Problem configuring a hub and spoke frame switch in 2520 series

From: Ifeanyi Eze (ieze@xxxxxxxxxxxx)
Date: Tue Jan 23 2001 - 12:33:30 GMT-3


   
Help please

Below is the config for the frame switch
interface serial 0
no ip address
encapsulation frame-relay
frame-relay intf-type dce
clockrate 64000
keepalive 15
frame-relay route 100 interface serial 2 201
!
interface serial 1
no ip address
encapsulation frame-relay
frame-relay intf-type dce
clockrate 64000
keepalive 15
frame-relay route 101 interface serial 2 102
!
interface serial 2
encapsulation frame-relay
frame-relay intf-type dce
clockrate 64000
keepalive 15
frame-relay route 201 interface serial 0 100
frame-relay route 102 interface serial 1 101

Spicey and Aton works fine through inverse-arp. Prasit s1 maintains up/up
status but with frame-relay dte, lmi, and pvc down. I have swapped cables,
interfaces and router to no avail. When I add keepalive 15 on Prasit s1, it
goes down.
Any help will be appreciated.

Eze



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:27:42 GMT-3