Hi Gurus,
Can someone help me to understand the problem bellow;
I created an EC between 3550 & 3750 (ports 23-24. Both pots were shut before
configuring). The 3550 was created as mode: desirable and the 3750 as mode:
ON. (I am hoping this is ok - so far)
On the 3750 I see the following error.
SW2(config-if-range)#do sh int gi1/0/23
GigabitEthernet1/0/23 is down, line protocol is down (err-disabled)
Whats causing this err-disable state?
The log looks like this
*Mar 1 08:12:37.200: %PM-4-ERR_DISABLE: channel-misconfig error detected on
Gi1/0/23, putting Gi1/0/23 in err-disable state
*Mar 1 08:12:37.200: %PM-4-ERR_DISABLE: channel-misconfig error detected on
Gi1/0/24, putting Gi1/0/24 in err-disable state.
The 3550 say both ports are down.
Whats the way around this? I tried a few things.... Change both ends to mode:
ON but same issue. Shut no shut same issues. Can anyone help?
Thanking you all in advance.
Jit
Blogs and organic groups at http://www.ccie.net
Received on Tue May 12 2009 - 20:19:39 ART
This archive was generated by hypermail 2.2.0 : Mon Jun 01 2009 - 07:04:42 ART