ISDN Backup With Dialer Watch

From: Evgeny Tantsura (ivgen@castel.nl)
Date: Thu Jan 02 2003 - 12:03:55 GMT-3


Hi,

My ISDN interface with Dialer Watch on it
is going down every idle-timeout and then dialing again.

interface Dialer1
 ip address 1.1.1.2 255.255.255.0
 encapsulation ppp
 ip ospf demand-circuit
 dialer pool 1
 dialer idle-timeout 180
 dialer string 0496406937
 dialer load-threshold 127 either
 dialer watch-group 1
 dialer-group 1
 pulse-time 0
 no cdp enable
 ppp authentication chap
 ppp multilink
end

access-list 170 deny ospf any any
access-list 170 permit ip any any
dialer watch-list 1 ip 192.168.5.1 255.255.255.255
dialer-list 1 protocol ip list 170
----------------------------------------------------

interface Dialer1
 ip address 1.1.1.1 255.255.255.0
 encapsulation ppp
 dialer pool 1
 dialer idle-timeout 180
 dialer load-threshold 50 either
 dialer-group 1
 no cdp enable
 ppp authentication chap

dialer-list 1 protocol ip permit

According to CCO it should stay connected until the router gets the
route via primery interface.

Any idea's ?

With kind regards/ met vriendelijke groeten,
------------------------------------------------
E. Tantsura
Network Developer
Essent Kabelcom N.V.
Dr.van Deenweg 84
8025BN Zwolle, The Netherlands
Tel: +31-(0)38-850-7642
Fax: +31-(0)38-850-7410
Mob: +31-(0)6-290-80458
------------------------------------------------
.



This archive was generated by hypermail 2.1.4 : Sat Feb 01 2003 - 07:33:39 GMT-3