From: Evgeny Tantsura (ivgen@castel.nl)
Date: Thu Jan 02 2003 - 12:03:55 GMT-3
Hi,
My ISDN interface with Dialer Watch on it
is going down every idle-timeout and then dialing again.
interface Dialer1
ip address 1.1.1.2 255.255.255.0
encapsulation ppp
ip ospf demand-circuit
dialer pool 1
dialer idle-timeout 180
dialer string 0496406937
dialer load-threshold 127 either
dialer watch-group 1
dialer-group 1
pulse-time 0
no cdp enable
ppp authentication chap
ppp multilink
end
access-list 170 deny ospf any any
access-list 170 permit ip any any
dialer watch-list 1 ip 192.168.5.1 255.255.255.255
dialer-list 1 protocol ip list 170
----------------------------------------------------
interface Dialer1
ip address 1.1.1.1 255.255.255.0
encapsulation ppp
dialer pool 1
dialer idle-timeout 180
dialer load-threshold 50 either
dialer-group 1
no cdp enable
ppp authentication chap
dialer-list 1 protocol ip permit
According to CCO it should stay connected until the router gets the
route via primery interface.
Any idea's ?
With kind regards/ met vriendelijke groeten,
------------------------------------------------
E. Tantsura
Network Developer
Essent Kabelcom N.V.
Dr.van Deenweg 84
8025BN Zwolle, The Netherlands
Tel: +31-(0)38-850-7642
Fax: +31-(0)38-850-7410
Mob: +31-(0)6-290-80458
------------------------------------------------
.
This archive was generated by hypermail 2.1.4 : Sat Feb 01 2003 - 07:33:39 GMT-3