From: Volkov, Dmitry (Toronto - BCE) (dmitry_volkov@xxxxxxxxx)
Date: Mon Aug 12 2002 - 17:50:10 GMT-3
Hi FUN,
As soon as You applied FRTS on major interface You already have default
map-class.
You can override the default for specific DLCI on a specific subint by using
frame-relay
class VC config command to assign the DLCI explicitly to a different class.
r1(config)#int s0/0
r1(config-if)#fr
r1(config-if)#fram
r1(config-if)#frame-relay tr
r1(config-if)#frame-relay traf
r1(config-if)#frame-relay traffic-shaping
r1(config-if)#^Z
r1#sh run int s0/0.1
08:19:24: %SYS-5-CONFIG_I: Configured from console by console
r1#sh traffic-shape
Interface Se0/0.1
Access Target Byte Sustain Excess Interval Increment Adapt
VC List Rate Limit bits/int bits/int (ms) (bytes)
Active
110 56000 875 7000 0 125 875 -
Interface Se0/0.2
Access Target Byte Sustain Excess Interval Increment Adapt
VC List Rate Limit bits/int bits/int (ms) (bytes)
Active
120 56000 875 7000 0 125 875 -
130 56000 875 7000 0 125 875 -
r1#
I don't have to have FRTS on S0/0.2 (VC 120, 130) but I get it as soon as I
applied FRTS on major interface.
Dmitry
-----Original Message-----
From: CCIE FUN [mailto:ccieexam2002@yahoo.com]
Sent: Monday, August 12, 2002 4:44 PM
To: Volkov, Dmitry (Toronto - BCE); 'ccielab@groupstudy.com'
Subject: Re: FRTS Solie Darth Reid
you apply FRTS map-class on a per DLCI basis.
under the s0.1
possibly you must have used the command
frame-relay interface dlci 110
that is when you enter the "Frame Relay DLCI
interface configuration mode "
you could then relate the map-class under this mode
with the following command
class "class name"
this command only configures the map-class under the
specified interface and does not interfere with s0.2
you should not see any config commands generated
automatically under s0.2
hope that helps
--- "Volkov, Dmitry (Toronto - BCE)"
<dmitry_volkov@ca.ml.com> wrote:
> Hi,
>
> I'm trying to do Solie's Darth Reid lab and I can't
> get FRTS working.
> According to Lab requirement (page 1149 sect III,
> i.4):
> "Configure FRTS on the PVC between R1 & R2 so that
> it responds to BECNS....,
> etc"
>
> R1 has one major serial 0 with two multipoint
> subinterfaces s0.1 and s0.2
> s0.1 has PVC 110 to R2, s0.2 has PVCs 120 and 130
> to the other routes via
> cloud.
>
> So I enabled FRTS on major interface and configured
> map-class and applied
> it to s0.1 (there is only one DLCI there).
> The same time doing like that I get default FRTS
> class-map on s0.2 with CIR
> 56000, etc.
>
> So I don't understand how it is possible to
> "disable" FRTS on other subint
> or particular DLCIs..
>
> I can configure GTS on subint basis but not FRTS,
>
> Did I miss something or Lab requirement is not
> correct ?
>
>
> Thanks,
>
> Dmitry
>
This archive was generated by hypermail 2.1.4 : Sat Sep 07 2002 - 19:48:23 GMT-3