From: Bruce Williams (bruce@xxxxxxxxxxxxxxxxxxxxxx)
Date: Thu Apr 18 2002 - 23:41:02 GMT-3
Is interface TokenRing 0 on a TokenRing Switch. If it is then the ring
number must match the number of the TRCRF and you have to convert it from
Hex to decimal before you enter it on the router.
Bruce
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
Babacar Diop
Sent: Thursday, April 18, 2002 10:00 PM
To: ccielab@groupstudy.com
Subject: DLSw question.
I have configured DLSw on two routers:
R5
Source-bridge ring-group 100
interface TokenRing0
ip address 133.14.33.1 255.255.255.0
ring-speed 16
source-bridge 10 1 100
R3
Source-bridge ring-group 100
interface TokenRing0
ip address 133.14.33.1 255.255.255.0
ring-speed 16
But everytime i applied "source-bridge 20 1 100" to
R3's T0 i get the follwing message on the console:
00:37:50: %TR-3-BADRNGNUM: Unit 0, ring number (20)
doesn't match established number (10).
00:37:50: %LANMGR-4-BADRNGNUM: Ring number mismatch on
TokenRing0, shutting down the interface
00:37:52: %LINK-5-CHANGED: Interface TokenRing0,
changed state to administratively down
Am i supposed to configure different virtual ring
numbers?
Thanks
This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:58:12 GMT-3