Re: DLSw question.

From: Nick Shah (nshah@xxxxxxxxxxxxxx)
Date: Thu Apr 18 2002 - 23:51:00 GMT-3


   
hmm..
I think you have connected both the routers to the same mau, if you have ,
then it wont accept same bridge numbers & same network ip addresses.

On another note you have same ip address configured on both the interfaces,
changing that could also resolve the issue.

Nick
-----Original Message-----
From: Babacar Diop <babacard2000@yahoo.com>
To: ccielab@groupstudy.com <ccielab@groupstudy.com>
Date: Friday, 19 April 2002 12:33
Subject: DLSw question.

>I have configured DLSw on two routers:
>
>R5
>Source-bridge ring-group 100
>interface TokenRing0
> ip address 133.14.33.1 255.255.255.0
> ring-speed 16
> source-bridge 10 1 100
>
>R3
>Source-bridge ring-group 100
>interface TokenRing0
> ip address 133.14.33.1 255.255.255.0
> ring-speed 16
>
>But everytime i applied "source-bridge 20 1 100" to
>R3's T0 i get the follwing message on the console:
>
>00:37:50: %TR-3-BADRNGNUM: Unit 0, ring number (20)
>doesn't match established number (10).
>00:37:50: %LANMGR-4-BADRNGNUM: Ring number mismatch on
>TokenRing0, shutting down the interface
>00:37:52: %LINK-5-CHANGED: Interface TokenRing0,
>changed state to administratively down
>
>Am i supposed to configure different virtual ring
>numbers?
>
>Thanks
>
>
>
>