Not to sound too redundant but we just ordered a bunch of Sup 6-E's as
well. The fix is simple:
DS4506-1BB-1#sh run | in hw
hw-module module 1 port-group 1 select gigabitethernet
hw-module module 1 port-group 2 select gigabitethernet
Done
On Sun, Jan 22, 2012 at 4:14 AM, faizan khurshid <
faizankhurshid921_at_hotmail.com> wrote:
> Hi Experts
>
> I have one Core WS-C4510R-E with WS-X45-SUP6-E .Im geeting following
> error
> once i reboot my Switch .A device can detect 10G ports but status remain
> down
> even using no shut commands
>
> I have TwinTenGig Converter installed on Core Switch
>
>
> C4K_GLMMAN-3-X2PLUGGABLESEEPROMREADFAILED:
> Failed to read seeprom on port Te2/8. Reinsert X2 module or configure
> GigabitEthernet port group if TwinGigConverter is installed.
>
>
> Any suggestion help will be highly appreciated
>
>
> Regards
>
> Faizan Khurshid
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
>
-- Thank you, Steve Di Bias CCIE #32840 Blogs and organic groups at http://www.ccie.netReceived on Sun Jan 22 2012 - 20:11:04 ART