Your clocking is wrong.
R1---radio1------radio2-----r2
One of rhe radio should be the clock source and u shou set both routers as a
receive or external clock. Ask what radio guy has set in his rAdios
On Thursday, September 22, 2011, shady darwish <engshad.shady_at_gmail.com>
wrote:
> Dear all ,
> I require E3 experts to assist me on the below configuration
>
> i configure ASR routers with E3 spa connected to NEC E3 Microwave link as
> below between two sites
>
> Site A
> interface Serial1/1/0
> description description +++Link To DAS USSC Microwave+++
> ip address 10.x.x.1 255.255.255.252
> ip ospf network point-to-point
> load-interval 30
> framing g751
> dsu bandwidth 34010
> clock source internal
>
> Site B
> interface Serial1/1/0
>
> ip address 10.x.x.2 255.255.255.252
> p ospf network point-to-point
> load-interval 30
> framing g751
> dsu bandwidth 34010
> clock source internal
>
> and something very strange happened from time to time the interface goes
> down without any no notification in one of the both sites and when i
remove
> the cable and i connect it agian it came up note that the local loop back
> test in both sites was success ed and the cables are new tested one
>
> is there any thing else need to be considered
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
Blogs and organic groups at http://www.ccie.net
Received on Thu Sep 22 2011 - 19:21:01 ART
This archive was generated by hypermail 2.2.0 : Sat Oct 01 2011 - 07:26:25 ART