Hi Guys,
I have cabled up my lab and I have issues with my access server. I am
wondering if anyone has experienced this problem.
Whenever I power up my lab and try to access the console of each device I
find I have to clear the line multiple times before the connection is
accepted.
It looks like you can't clear a range of lines either and this becomes very
time consuming and annoying.
Any Ideas?
CCIE-LAB(config)#ip host R1 2001 10.0.0.1
CCIE-LAB(config)#exit
CCIE-LAB#R1
Trying R1 (10.0.0.1, 2001)...
% Connection refused by remote host
CCIE-LAB#clear line 1
[confirm]
[OK]
CCIE-LAB#R1
Trying R1 (10.0.0.1, 2001)...
% Connection refused by remote host
CCIE-LAB#clear line 1
[confirm]
[OK]
CCIE-LAB#R1
Trying R1 (10.0.0.1, 2001)...
% Connection refused by remote host
CCIE-LAB#clear line 1
[confirm]
[OK]
CCIE-LAB#R1
Trying R1 (10.0.0.1, 2001)... Open
R1>en
R1#
Thanks,
-Aaron
Blogs and organic groups at http://www.ccie.net
Received on Thu Mar 17 2011 - 09:28:35 ART