For the first option It's not a problem that some devices don't
support Q-in-Q, as long as at least the 2 endpoints support it.
I don't see your second option to work as the Nortel switch actively
needs to forward the VTP advertisements and I don't see it doing that.
Third option: aahm indeed you did ;-)
-- Regards, Rick Mur CCIE2 #21946 (R&S / Service Provider) Sr. Support Engineer IPexpert, Inc. URL: http://www.IPexpert.com On 1 okt 2009, at 15:38, Rob Clav wrote: > Hi folks, > I'm challenged to use vtp where the vtp server switch is behind a > Nortel > Switch. > > First option: Using QinQ tunnel. Problem, some devices are 2960 that > seem > they don't support QinQ. > Second option: Try to active vtp protocol at the trunk connecting > nortel > switch, and let`s see if nortel,don't modify dtp and send them > thought the > nortel to the opposite site. > Third option: Write down and send this problem to the groupstudy > mail... > > I didn't try the options yet, because the switches are at non-stop > environment. > Many thanks, > Robclav > > > Blogs and organic groups at http://www.ccie.net > > _______________________________________________________________________ > Subscription information may be found at: > http://www.groupstudy.com/list/CCIELab.html Blogs and organic groups at http://www.ccie.netReceived on Thu Oct 01 2009 - 16:40:25 ART
This archive was generated by hypermail 2.2.0 : Sun Nov 01 2009 - 07:50:59 ART