Test-Switch#sh int fa1/0/1 cap
FastEthernet1/0/1
Model: ME-C3750-24TE
Type: 10/100BaseTX
Speed: 10,100,auto
Duplex: half,full,auto
Trunk encap. type: 802.1Q,ISL
Trunk mode: on,off,desirable,nonegotiate
Channel: yes
Broadcast suppression: percentage(0-100)
Flowcontrol: rx-(off,on,desired),tx-(none)
Fast Start: yes
QoS scheduling: rx-(not configurable on per port basis),tx-(4q2t)
CoS rewrite: yes
ToS rewrite: yes
UDLD: yes
*Inline power: no
* SPAN: source/destination
PortSecure: yes
Dot1x: yes
HTH
On Mon, Jun 29, 2009 at 3:01 PM, CCIE <ccie_at_axizo.com> wrote:
> Hi Experts,
>
> How I can check if my switch port support inline power or PoE?
>
> Regards,
>
> Amin
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
Blogs and organic groups at http://www.ccie.net
Received on Mon Jun 29 2009 - 15:08:59 ART