You can do that and play with the timers, as well as set the 'max suppress'
timer to 30. Due to the nature of the 1/2 life timer, the penalty begins to
decay immediately. This makes it kind of harder to set the time to be
exactly 30 seconds.
The initial question from Antonio is a bit unclear to me since the first
flap does not suppress the interface ... but I believe it should be how to
make this "reset or unsuppressed 30 seconds from the initial suppress time".
By default, the max suppress time is 20 seconds, so some configs are needed
to make this 30 second goal happen.
I could not get it to be exact ... but using the command line I came close.
Would be interested to hear if you were able to get this to be an exact
thing. I may have overlooked something.
On Mon, May 18, 2009 at 9:21 AM, Renash Chandran <zyberpal_at_gmail.com> wrote:
> How about setting the half-life to 30sec and suppress threshold to 3000.. I
> think this should do the trick.
> Ren
>
>
>
>
> On Sun, May 17, 2009 at 11:15 AM, ALL From_NJ <all.from.nj_at_gmail.com>wrote:
>
>> Hello,
>>
>> I had to look this up .. good question, thanks.
>>
>> I think you partly answered the question ... in a round about way. Here
>> is
>> the guide (watch the ugly word wrap):
>>
>> http://www.cisco.com/en/US/docs/ios/iproute/command/reference/irp_pi1.html#wp1011620
>>
>> Making the interface become suppressed is not hard ... and the penalty
>> begins to decay. The answer is in the configs, although when I was
>> testing
>> this I was only able to get it to be exactly 30 seconds in one of my
>> tests;
>> apart from this the time was always a few seconds below.
>>
>> I used the debug command to verify the configs and times.
>>
>> - debug dampening interface -
>>
>> I just could not get it to be exactly 30 seconds.
>>
>> Team - would this be an issue? HTH,
>>
>> Andrew Lee Lissitz
>>
>>
>>
>> On Sat, May 16, 2009 at 2:17 PM, Antonio Gonzales Chaves <
>> ccieantony_at_gmail.com> wrote:
>>
>> > Hi All,
>> > I'm stuck with a dampening issue. It ask me to dump a router
>> > interface if it flapped 3 times in a 30 second period. I know that every
>> > flap penalized the interface with 1000. If I configure the suppress
>> > threshold in 2001, with 3 flaps the interface is out. The question is,
>> how
>> > can I made the penalty reset after 30 seconds from the first flap?
>> >
>> >
>> > Thanks in advance,
>> > Antony.
>> >
>> >
>> > Blogs and organic groups at http://www.ccie.net
>> >
>> > _______________________________________________________________________
>> > Subscription information may be found at:
>> > http://www.groupstudy.com/list/CCIELab.html
>> >
>> >
>> >
>> >
>> >
>> >
>> >
>> >
>>
>>
>> --
>> Andrew Lee Lissitz
>> all.from.nj_at_gmail.com
>>
>>
>> Blogs and organic groups at http://www.ccie.net
>>
>> _______________________________________________________________________
>> Subscription information may be found at:
>> http://www.groupstudy.com/list/CCIELab.html
>>
>>
>>
>>
>>
>>
>>
>>
>
>
> --
> Luv,
> Ren......
>
-- Andrew Lee Lissitz all.from.nj_at_gmail.com Blogs and organic groups at http://www.ccie.netReceived on Mon May 18 2009 - 11:23:48 ART