Re: RMON Error

From: Bryan Bartik <bbartik_at_ipexpert.com>
Date: Mon, 18 May 2009 09:02:22 -0600

use a lower case i.

ifOutQLen.4

On Mon, May 18, 2009 at 8:56 AM, Splinter <splinter330_at_gmail.com> wrote:

> Bryan,
>
> not working this is the error: Unknown object: IfOutQLen.4
>
> Splinter
>
>
> On Mon, May 18, 2009 at 4:52 PM, Bryan Bartik <bbartik_at_ipexpert.com>wrote:
>
>> Splinter,
>>
>> You have to specify the interface index after ifOutQLen. If your s2/0 is
>> interface 4 then:
>>
>> rmon alarm 1 ifOutQLen.4 30 absolute rising-threshold 40 1
>> falling-threshold 0 2
>>
>> Bryan Bartik
>> CCIE #23707 (R&S), CCNP
>> Sr. Support Engineer - IPexpert, Inc.
>> URL: http://www.IPexpert.com
>>
>>
>>
>> On Mon, May 18, 2009 at 8:38 AM, Splinter <splinter330_at_gmail.com> wrote:
>>
>>> Hello Sir,
>>>
>>> I am getting an "Alarm creation failure"
>>>
>>> R6#sh snmp mib ifmib ifindex
>>> FastEthernet0/0: Ifindex = 2
>>> Loopback0: Ifindex = 13
>>> Null0: Ifindex = 8
>>> Serial2/0: Ifindex = 4
>>> Virtual-Access2: Ifindex = 25
>>> FastEthernet0/1: Ifindex = 3
>>> Serial2/1: Ifindex = 5
>>> Serial2/2: Ifindex = 6
>>> Serial2/3: Ifindex = 7
>>> FastEthernet0/0.26-mpls layer: Ifindex = 16
>>> FastEthernet0/0.67-mpls layer: Ifindex = 18
>>> FastEthernet0/0.26-802.1Q vLAN subif: Ifindex = 15
>>> FastEthernet0/0.67-802.1Q vLAN subif: Ifindex = 17
>>>
>>> Splinter
>>>
>>>
>>> On Mon, May 18, 2009 at 4:31 PM, Shaughn Smith <
>>> Shaughn.Smith_at_mtnbusiness.co.za> wrote:
>>>
>>> > Do this, to get the specific interface mib
>>> >
>>> > Test#sh snmp mib ifmib ifindex
>>> > Async0/0/0: Ifindex = 5
>>> > FastEthernet0/0: Ifindex = 1
>>> > Loopback0: Ifindex = 7
>>> > Null0: Ifindex = 4
>>> > Serial0/0/0: Ifindex = 3
>>> > Loopback1: Ifindex = 8
>>> > FastEthernet0/1: Ifindex = 2
>>> > Serial0/0/0.101: Ifindex = 6
>>> >
>>> > Then this
>>> >
>>> > rmon alarm 1 ifEntry.3 (<------ from step 1, ie serial0/0) 30 absolute
>>> > rising threshold 40 1 falling-threshold 0
>>> > 2
>>> >
>>> >
>>> >
>>> > -----Original Message-----
>>> > From: nobody_at_groupstudy.com [mailto:nobody_at_groupstudy.com] On Behalf
>>> Of
>>> > Splinter
>>> > Sent: Monday, May 18, 2009 3:58 PM
>>> > To: ccielab_at_groupstudy.com
>>> > Subject: RMON Error
>>> >
>>> > Hello,
>>> >
>>> > when I configure my rmon alarm i get the following error:
>>> >
>>> > Unknown object: ifOutQlen
>>> >
>>> > where am i going wrong?
>>> >
>>> > here is my config:
>>> >
>>> > snmp-server ifindex persist
>>> > snmp-server community public
>>> > snmp-server enable traps syslog
>>> >
>>> > rmon event 1 log trap public description "serial 2/0 output queue full"
>>> > owner cisco
>>> > rmon event 2 log trap public description "serial 2/0 output queue OK"
>>> owner
>>> > cisco
>>> > rmon alarm 1 ifOutQlen 30 absolute rising threshold 40 1
>>> falling-threshold
>>> > 0
>>> > 2 <= "this is were i am getting the error"
>>> >
>>> > the sampling MIB vlaue is ifEntry.21
>>> >
>>> > please help failing to get the correct IfEntry.
>>> >
>>> > Splinter
>>> >
>>> >
>>> > Blogs and organic groups at http://www.ccie.net
>>> >
>>> > _______________________________________________________________________
>>> > Subscription information may be found at:
>>> > http://www.groupstudy.com/list/CCIELab.html
>>>
>>>
>>> Blogs and organic groups at http://www.ccie.net
>>>
>>> _______________________________________________________________________
>>> Subscription information may be found at:
>>> http://www.groupstudy.com/list/CCIELab.html
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>
>>
>> --
>>
>>
>

-- 
Bryan Bartik
CCIE #23707 (R&S), CCNP
Sr. Support Engineer - IPexpert, Inc.
URL: http://www.IPexpert.com
Blogs and organic groups at http://www.ccie.net
Received on Mon May 18 2009 - 09:02:22 ART

This archive was generated by hypermail 2.2.0 : Mon Jun 01 2009 - 07:04:43 ART