Re: RMON Error

From: Splinter <splinter330_at_gmail.com>
Date: Mon, 18 May 2009 16:56:44 +0200

Bryan,

not working this is the error: Unknown object: IfOutQLen.4

Splinter

On Mon, May 18, 2009 at 4:52 PM, Bryan Bartik <bbartik_at_ipexpert.com> wrote:

> Splinter,
>
> You have to specify the interface index after ifOutQLen. If your s2/0 is
> interface 4 then:
>
> rmon alarm 1 ifOutQLen.4 30 absolute rising-threshold 40 1
> falling-threshold 0 2
>
> Bryan Bartik
> CCIE #23707 (R&S), CCNP
> Sr. Support Engineer - IPexpert, Inc.
> URL: http://www.IPexpert.com
>
>
>
> On Mon, May 18, 2009 at 8:38 AM, Splinter <splinter330_at_gmail.com> wrote:
>
>> Hello Sir,
>>
>> I am getting an "Alarm creation failure"
>>
>> R6#sh snmp mib ifmib ifindex
>> FastEthernet0/0: Ifindex = 2
>> Loopback0: Ifindex = 13
>> Null0: Ifindex = 8
>> Serial2/0: Ifindex = 4
>> Virtual-Access2: Ifindex = 25
>> FastEthernet0/1: Ifindex = 3
>> Serial2/1: Ifindex = 5
>> Serial2/2: Ifindex = 6
>> Serial2/3: Ifindex = 7
>> FastEthernet0/0.26-mpls layer: Ifindex = 16
>> FastEthernet0/0.67-mpls layer: Ifindex = 18
>> FastEthernet0/0.26-802.1Q vLAN subif: Ifindex = 15
>> FastEthernet0/0.67-802.1Q vLAN subif: Ifindex = 17
>>
>> Splinter
>>
>>
>> On Mon, May 18, 2009 at 4:31 PM, Shaughn Smith <
>> Shaughn.Smith_at_mtnbusiness.co.za> wrote:
>>
>> > Do this, to get the specific interface mib
>> >
>> > Test#sh snmp mib ifmib ifindex
>> > Async0/0/0: Ifindex = 5
>> > FastEthernet0/0: Ifindex = 1
>> > Loopback0: Ifindex = 7
>> > Null0: Ifindex = 4
>> > Serial0/0/0: Ifindex = 3
>> > Loopback1: Ifindex = 8
>> > FastEthernet0/1: Ifindex = 2
>> > Serial0/0/0.101: Ifindex = 6
>> >
>> > Then this
>> >
>> > rmon alarm 1 ifEntry.3 (<------ from step 1, ie serial0/0) 30 absolute
>> > rising threshold 40 1 falling-threshold 0
>> > 2
>> >
>> >
>> >
>> > -----Original Message-----
>> > From: nobody_at_groupstudy.com [mailto:nobody_at_groupstudy.com] On Behalf Of
>> > Splinter
>> > Sent: Monday, May 18, 2009 3:58 PM
>> > To: ccielab_at_groupstudy.com
>> > Subject: RMON Error
>> >
>> > Hello,
>> >
>> > when I configure my rmon alarm i get the following error:
>> >
>> > Unknown object: ifOutQlen
>> >
>> > where am i going wrong?
>> >
>> > here is my config:
>> >
>> > snmp-server ifindex persist
>> > snmp-server community public
>> > snmp-server enable traps syslog
>> >
>> > rmon event 1 log trap public description "serial 2/0 output queue full"
>> > owner cisco
>> > rmon event 2 log trap public description "serial 2/0 output queue OK"
>> owner
>> > cisco
>> > rmon alarm 1 ifOutQlen 30 absolute rising threshold 40 1
>> falling-threshold
>> > 0
>> > 2 <= "this is were i am getting the error"
>> >
>> > the sampling MIB vlaue is ifEntry.21
>> >
>> > please help failing to get the correct IfEntry.
>> >
>> > Splinter
>> >
>> >
>> > Blogs and organic groups at http://www.ccie.net
>> >
>> > _______________________________________________________________________
>> > Subscription information may be found at:
>> > http://www.groupstudy.com/list/CCIELab.html
>>
>>
>> Blogs and organic groups at http://www.ccie.net
>>
>> _______________________________________________________________________
>> Subscription information may be found at:
>> http://www.groupstudy.com/list/CCIELab.html
>>
>>
>>
>>
>>
>>
>>
>>
>
>
> --

Blogs and organic groups at http://www.ccie.net
Received on Mon May 18 2009 - 16:56:44 ART

This archive was generated by hypermail 2.2.0 : Mon Jun 01 2009 - 07:04:43 ART