Hi Thameem,
Back2back frame-relay?
I assume you have configured encapsulations and dlci's ok, check if you have
'no keepalive' on both sides as you dont have LMI OR frame-relay switching
on one router together with frame-relay intf-type dce on the dce.
If that doesnt work, check show interface if you have all signals if the
above doesnt work or contact your rental company?
2009/4/5 Thameem Maranveetil Parambath <tparamba_at_thecontactcentre.ae>
> Can someone help me in this please.
>
> I have rented remote lab. On R3 and R5 I am trying to configure frame
> relay. But
>
> sh ip int br shows s0/0 as down , down
>
> sh controllers s0/0 is saying DTE V.35 clocks stopped.
>
> Why this should happen? Is it because the DCE is not configured with clock
> rate?
>
> Warm Regards
> Thameem
>
>
>
> -----------------------------------------
> The content of this email together with any attachments, statements
> and opinions expressed herein contains information that is private
> and confidential, are intended for the named addressee/s only. If
> you are not the addressee of this email you may not copy, forward,
> disclose or otherwise use it or any part of it in any form
> whatsoever. If you have received this message in error, please
> notify postmaster_at_etisalat.ae by email immediately and delete the
> message without making any copies.
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
>
-- Wouter Prins wp_at_null0.nl 0x301FA912 Blogs and organic groups at http://www.ccie.netReceived on Sun Apr 05 2009 - 15:50:05 ART
This archive was generated by hypermail 2.2.0 : Mon May 04 2009 - 07:39:11 ART