From: Rich Collins (nilsi2002@gmail.com)
Date: Mon Mar 17 2008 - 19:37:43 ART
The load-balancing is only applicable local to the switch. It doesn't sync
this configuration with the far side nor does it need to be symmetric or
reverse of that with the far end.
-Rich
On 3/17/08, Kevin Howard <kevin@leh.net> wrote:
>
> Hello,
> in looking through the doccd I cannot find this answer - when configuring
> load-bal on etherchannel, does the load-balacing scheme chosen need to be
> same on each side? When I lab it matching and not matching, there are no
> errors indicating a problem, just want to check with the group.
>
> thanks.
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html