From: Petr Lapukhov (petr@internetworkexpert.com)
Date: Sat Jun 17 2006 - 16:21:33 ART
Victor,
AFAIR the goal was to use MINIMUM manual FR mappings. The best
way do that is to use Inverse-ARP, thus ending with zero number of
static mappings.
All you need to do is just put unnecessary DLCIs out of the dynamic
business with "no frame-relay inverse-arp IP"
HTH
-- Petr Lapukhov, CCIE #16379 petr@internetworkexpert.comInternetwork Expert, Inc. http://www.InternetworkExpert.com Toll Free: 877-224-8987 Outside US: 775-826-4344 24/7 Support: http://forum.internetworkexpert.com Live Chat: http://www.internetworkexpert.com/chat/