Re: about the cat6 cable

From: James Ventre (messageboard@ventrefamily.com)
Date: Mon Apr 24 2006 - 09:55:33 GMT-3


That card supports Auto-MDIX. I would just use a straight through cable
and let it do it's thing.

6500> sh port capabilities 4/1
Model WS-X6748-GE-TX
Port 4/1
Type 10/100/1000
Auto MDIX yes
AuxiliaryVlan 1..4094,untagged,dot1p,none
Broadcast suppression percentage(0-100)
Channel yes
COPS port group 4/1-24
CoS rewrite yes
Dot1q-all-tagged yes
Dot1x yes
Duplex half,full
Fast start yes
Flow control receive-(off,on,desired),send-(off,on,desired)
Inline power no
Jumbo frames yes
Link debounce timer yes
Link debounce timer delay no
Membership static,dynamic
Port ASIC group 4/1-12
Port Security ACL yes
Port VLAN Mapping Group: 4/1-12 Maximum Allowed Mappings: 128
Port VLAN Mapping Supported Trunk Type: dot1q, ISL
QOS scheduling rx-(1q8t),tx-(1p3q8t)
Security yes
SPAN source,destination
Speed auto,10,100,1000,auto-10-100
Sync restart delay no
ToS rewrite DSCP
Trunk encap type 802.1Q,ISL
Trunk mode on,off,desirable,auto,nonegotiate
UDLD yes

James

Tom Young wrote:
> For connect two WS-6748-GE-TX modules, I should use a four
> Twisted-Pair Crossover Cable ,because it is a 1000BaseT
> connection. I use the cat6 crossover cable.
> My question is : does all of the cat6 crosscable are four
> Twisted-Pair Crossover Cable by default?
>
> thanks alot
>
> attach: pin layout of my want.
> http://www.cabling-design.com/references/pinouts/1000base_t_crossover.shtml



This archive was generated by hypermail 2.1.4 : Mon May 01 2006 - 11:41:59 GMT-3