From: Tom Young (gitsyoung@yahoo.co.jp)
Date: Mon Apr 24 2006 - 10:01:14 GMT-3
Use the Auto-mdix function is not important, what I want
to know is if all of the cat6 cross cable are FOUR
Twisted-Pair Crossover Cable ?
--- James Ventre <messageboard@ventrefamily.com> $B$+$i$N(B
$B%a%C%;!<%8!'(B
> That card supports Auto-MDIX. I would just use a
> straight through cable
> and let it do it's thing.
>
> 6500> sh port capabilities 4/1
> Model WS-X6748-GE-TX
> Port 4/1
> Type 10/100/1000
> Auto MDIX yes
> AuxiliaryVlan
> 1..4094,untagged,dot1p,none
> Broadcast suppression percentage(0-100)
> Channel yes
> COPS port group 4/1-24
> CoS rewrite yes
> Dot1q-all-tagged yes
> Dot1x yes
> Duplex half,full
> Fast start yes
> Flow control
> receive-(off,on,desired),send-(off,on,desired)
> Inline power no
> Jumbo frames yes
> Link debounce timer yes
> Link debounce timer delay no
> Membership static,dynamic
> Port ASIC group 4/1-12
> Port Security ACL yes
> Port VLAN Mapping Group: 4/1-12
> Maximum Allowed Mappings: 128
> Port VLAN Mapping Supported Trunk Type:
> dot1q, ISL
> QOS scheduling rx-(1q8t),tx-(1p3q8t)
> Security yes
> SPAN source,destination
> Speed
> auto,10,100,1000,auto-10-100
> Sync restart delay no
> ToS rewrite DSCP
> Trunk encap type 802.1Q,ISL
> Trunk mode
> on,off,desirable,auto,nonegotiate
> UDLD yes
>
> James
>
>
>
>
>
> Tom Young wrote:
> > For connect two WS-6748-GE-TX modules, I should
> use a four
> > Twisted-Pair Crossover Cable ,because it is a
> 1000BaseT
> > connection. I use the cat6 crossover cable.
> > My question is : does all of the cat6 crosscable
> are four
> > Twisted-Pair Crossover Cable by default?
> >
> > thanks alot
> >
> > attach: pin layout of my want.
> >
>
http://www.cabling-design.com/references/pinouts/1000base_t_crossover.shtml
> >
>
--------------------------------------