From: James Ventre (messageboard@ventrefamily.com)
Date: Mon Apr 24 2006 - 10:22:25 GMT-3
It depends on the cable manufacturer.  I've seen Cat6 come both ways (2
pairs crossed or 4 pairs crossed).
James
Tom Young wrote:
  Use the Auto-mdix function is not important, what I want
  to know is if all of the cat6 cross cable are FOUR
  Twisted-Pair Crossover Cable ?
  --- James Ventre   <messageboard@ventrefamily.com>   $B$+$i$N(B
  $B%a%C%;!<%8!'(B
    That card supports Auto-MDIX.  I would just use a
    straight through cable 
    and let it do it's thing.
    
    6500> sh port capabilities 4/1
    Model                       WS-X6748-GE-TX
    Port                        4/1
    Type                        10/100/1000
    Auto MDIX                   yes
    AuxiliaryVlan              
    1..4094,untagged,dot1p,none
    Broadcast suppression       percentage(0-100)
    Channel                     yes
    COPS port group             4/1-24
    CoS rewrite                 yes
    Dot1q-all-tagged            yes
    Dot1x                       yes
    Duplex                      half,full
    Fast start                  yes
    Flow control               
    receive-(off,on,desired),send-(off,on,desired)
    Inline power                no
    Jumbo frames                yes
    Link debounce timer         yes
    Link debounce timer delay   no
    Membership                  static,dynamic
    Port ASIC group             4/1-12
    Port Security ACL           yes
    Port VLAN Mapping           Group: 4/1-12    
    Maximum Allowed Mappings: 128
    Port VLAN Mapping           Supported Trunk Type:
    dot1q, ISL
    QOS scheduling              rx-(1q8t),tx-(1p3q8t)
    Security                    yes
    SPAN                        source,destination
    Speed                      
    auto,10,100,1000,auto-10-100
    Sync restart delay          no
    ToS rewrite                 DSCP
    Trunk encap type            802.1Q,ISL
    Trunk mode                 
    on,off,desirable,auto,nonegotiate
    UDLD                        yes
    
    James
    Tom Young wrote:
      For connect two WS-6748-GE-TX modules, I should
    use a four
      Twisted-Pair Crossover Cable ,because it is a
    1000BaseT
      connection. I use the cat6 crossover cable.
      My question is : does all of the cat6 crosscable
    are four
      Twisted-Pair Crossover Cable by default?
      
      thanks alot
      
      attach: pin layout of my want.
  http://www.cabling-design.com/references/pinouts/1000base_t_crossover.shtml    
  --------------------------------------
  Celebrate Yahoo! JAPAN 10th Anniversary  http://pr.mail.yahoo.co.jp/10thann/  