RE: Frame-relay BW statement question

From: Schulz, Dave (DSchulz@dpsciences.com)
Date: Thu Mar 16 2006 - 10:18:01 GMT-3


Chris - This is a bit long, so I apologize for the length. Here is the
unedited show commands. Thanks!

MINN#sh run

Building configuration...

Current configuration : 2410 bytes

!

version 12.2

service timestamps debug datetime msec

service timestamps log datetime msec

no service password-encryption

!

hostname MINN

!

logging buffered 4096 debugging

enable secret 5 $1$h7ki$YbeBkXhidPMtT9oG2.DWY.

enable password epass

!

username CHGO password 0 chicago

clock timezone CST -6

ip subnet-zero

!

!

no ip domain lookup

ip host isdnchgo 192.168.254.41

!

ip cef

ip audit notify log

ip audit po max-events 100

!

isdn switch-type basic-ni

!

!

!

interface BRI0

 ip address 192.168.254.42 255.255.255.252

 encapsulation ppp

 dialer idle-timeout 90

 dialer map ip 192.168.254.41 name CHGO broadcast 18158363379

 dialer load-threshold 3 outbound

 dialer-group 1

 isdn switch-type basic-ni

 isdn spid1 65140502581111

 isdn spid2 65140502621111

 isdn T203 10000

 no fair-queue

 no cdp enable

 ppp authentication chap

 ppp multilink

!

interface FastEthernet0

 ip address 192.168.110.1 255.255.255.0 secondary

 ip address 172.18.0.1 255.255.0.0

 ip helper-address 172.25.0.2

 ip helper-address 172.16.21.1

 ip probe proxy

 speed 10

 arp probe

 no cdp enable

 bridge-group 1

!

interface Serial0

 no ip address

 encapsulation frame-relay

 no ip route-cache cef

 no ip mroute-cache

 no fair-queue

 service-module t1 timeslots 1-12

 arp probe

 frame-relay ip rtp header-compression

!

interface Serial0.302 point-to-point

 description Frame Relay to Chicago

 bandwidth 384

 ip address 192.168.254.10 255.255.255.252

 no ip mroute-cache

 shutdown

 no cdp enable

 frame-relay interface-dlci 300

 frame-relay ip rtp header-compression

 bridge-group 1

!

interface Serial0.330 point-to-point

 description Frame Relay to CTI_Romeo

 ip address 192.168.250.10 255.255.255.252

 no ip mroute-cache

 no cdp enable

 frame-relay interface-dlci 330

 frame-relay ip rtp header-compression

 bridge-group 1

!

router eigrp 20

 network 172.18.0.0

 network 192.168.250.0

 network 192.168.254.0

 no auto-summary

 no eigrp log-neighbor-changes

!

ip classless

ip route 0.0.0.0 0.0.0.0 192.168.250.9 250

ip route 172.25.0.0 255.255.0.0 192.168.254.41 242

ip route 172.28.0.0 255.255.0.0 192.168.254.41 242

no ip http server

!

!

access-list 100 deny eigrp any any

access-list 100 permit ip any any

dialer-list 1 protocol ip list 100

no cdp run

!

bridge 1 protocol ieee

!

line con 0

 password rmsbus

 logging synchronous

 login

line aux 0

 password rmsbus

 login

line vty 0 4

 password misvt

 logging synchronous

 login

!

end

MINN# sh ver

Cisco Internetwork Operating System Software

IOS (tm) C1700 Software (C1700-NO3SY7-M), Version 12.2(11)T11, RELEASE
SOFTWARE (fc1)

Technical Support: http://www.cisco.com/techsupport

Copyright (c) 1986-2004 by cisco Systems, Inc.

Compiled Wed 14-Apr-04 16:22 by hqluong

Image text-base: 0x80008124, data-base: 0x80C6242C

ROM: System Bootstrap, Version 12.2(7r)XM2, RELEASE SOFTWARE (fc1)

ROM: C1700 Software (C1700-NO3SY7-M), Version 12.2(11)T11, RELEASE
SOFTWARE (fc1)

MINN uptime is 1 week, 5 days, 13 hours, 47 minutes

System returned to ROM by power-on

System image file is "flash:c1700-no3sy7-mz.122-11.t11.bin"

cisco 1721 (MPC860P) processor (revision 0x300) with 58983K/6553K bytes
of memory.

Processor board ID FOC081538NL (2911319025), with hardware revision 0000

MPC860P processor: part number 5, mask 2

Bridging software.

X.25 software, Version 3.0.0.

Basic Rate ISDN software, Version 1.1.

1 FastEthernet/IEEE 802.3 interface(s)

1 Serial network interface(s)

1 ISDN Basic Rate interface(s)

WIC T1-DSU

32K bytes of non-volatile configuration memory.

32768K bytes of processor board System flash (Read/Write)

Configuration register is 0x2102

MINN#sh frame map

Serial0.302 (administratively down): point-to-point dlci, dlci
300(0x12C,0x48C0), broadcast

          status deleted,

              RTP Header Compression (inherited), connections: 256

Serial0.330 (up): point-to-point dlci, dlci 330(0x14A,0x50A0),
broadcast, BW = 256000

          status defined, active,

              RTP Header Compression (inherited), connections: 256

MINN#sh frame pvc

PVC Statistics for interface Serial0 (Frame Relay DTE)

              Active Inactive Deleted Static

  Local 1 0 1 0

  Switched 0 0 0 0

  Unused 0 0 0 0

DLCI = 300, DLCI USAGE = LOCAL, PVC STATUS = DELETED, INTERFACE =
Serial0.302

  input pkts 0 output pkts 0 in bytes 0

  out bytes 0 dropped pkts 0 in pkts dropped 0

  out pkts dropped 0 out bytes dropped 0

  in FECN pkts 0 in BECN pkts 0 out FECN pkts 0

  out BECN pkts 0 in DE pkts 0 out DE pkts 0

  out bcast pkts 0 out bcast bytes 0

  5 minute input rate 0 bits/sec, 0 packets/sec

  5 minute output rate 0 bits/sec, 0 packets/sec

  pvc create time 1w5d, last time pvc status changed 1d04h

DLCI = 330, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE =
Serial0.330

  input pkts 489643 output pkts 301311 in bytes 64961329

  out bytes 19931415 dropped pkts 0 in pkts dropped 0

  out pkts dropped 0 out bytes dropped 0

  in FECN pkts 6096 in BECN pkts 0 out FECN pkts 0

  out BECN pkts 0 in DE pkts 0 out DE pkts 0

  out bcast pkts 13183 out bcast bytes 843320

  5 minute input rate 13000 bits/sec, 12 packets/sec

  5 minute output rate 6000 bits/sec, 8 packets/sec

  pvc create time 1w5d, last time pvc status changed 1d04h

MINN#sh int s0

Serial0 is up, line protocol is up

  Hardware is PQUICC with Fractional T1 CSU/DSU

  MTU 1500 bytes, BW 768 Kbit, DLY 20000 usec,

     reliability 255/255, txload 1/255, rxload 3/255

  Encapsulation FRAME-RELAY, loopback not set

  Keepalive set (10 sec)

  ARP type: PROBE

  LMI enq sent 6094, LMI stat recvd 6094, LMI upd recvd 0, DTE LMI up

  LMI enq recvd 0, LMI stat sent 0, LMI upd sent 0

  LMI DLCI 1023 LMI type is CISCO frame relay DTE

  FR SVC disabled, LAPF state down

  Broadcast queue 0/64, broadcasts sent/dropped 13187/0, interface
broadcasts 13187

  Last input 00:00:00, output 00:00:00, output hang never

  Last clearing of "show interface" counters 16:55:44

  Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0

  Queueing strategy: fifo

  Output queue :0/40 (size/max)

  5 minute input rate 10000 bits/sec, 9 packets/sec

  5 minute output rate 3000 bits/sec, 6 packets/sec

     495798 packets input, 65052579 bytes, 0 no buffer

     Received 69388 broadcasts, 0 runts, 0 giants, 0 throttles

     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort

     307437 packets output, 20014614 bytes, 0 underruns

     0 output errors, 0 collisions, 0 interface resets

     0 output buffer failures, 0 output buffers swapped out

     0 carrier transitions

     DCD=up DSR=up DTR=up RTS=up CTS=up

Dave Schulz,

Email: dschulz@dpsciences.com <mailto:dschulz@dpsciences.com%20>

________________________________

From: Chris Lewis [mailto:chrlewiscsco@gmail.com]
Sent: Wednesday, March 15, 2006 5:26 PM
To: Schulz, Dave
Cc: ccielab@groupstudy.com
Subject: Re: Frame-relay BW statement question

This does not look right to me.

To my knowledge, there is nothing in IOS that connects clock rate to an
IOS displayed bandwidth statement.

Could you post the device configs and the unedited show command outputs?

On my routers I have a clock rate defined of 72000, however my show
commands display the following:

R1#sho fram map
Serial0/0.12 (up): point-to-point dlci, dlci 102(0x66,0x1860), broadcast
          status defined, active
R1#sho int s0/0.12
Serial0/0.12 is up, line protocol is up
  Hardware is PowerQUICC Serial
  Internet address is 12.12.12.1/24
  MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation FRAME-RELAY
  Last clearing of "show interface" counters never
R1#

On 3/15/06, Schulz, Dave <DSchulz@dpsciences.com> wrote:

Group - I have a frame relay question..... on the following show frame
map, it shows BW=256000. The documentation is a bit silent on this
issue, but is this determined by the cir of the line, or, the clock
speed that the interface is receiving. There is no bandwidth statement
configured. TIA.

MINN#sh frame map
Serial0.302 (administratively down): point-to-point dlci, dlci
300(0x12C,0x48C0)
, broadcast
         status deleted,
             RTP Header Compression (inherited), connections: 256
Serial0.330 (up): point-to-point dlci, dlci 330(0x14A,0x50A0),
broadcast, BW = 256000
         status defined, active,
             RTP Header Compression (inherited), connections: 256

Dave