From: David Cearlock (dcgroupstudy@gmail.com)
Date: Sun May 22 2005 - 10:36:40 GMT-3
Software Version: 12.1(8a)E
My company bought some new lab equipment and I am having trouble with
one of the cards. I installed a new PA-MC-4T1 in a 7200. When I do a
show
controllers I see the below. However, the interfaces do not appear when using
the show interface command but all other interfaces do. Am I missing a step in
the installation process?
We have two PA-MC-4T1 cards and both have the same result. I have
reloaded and there was no change.
7204#sho controllers t1
T1 2/0 is down.
Applique type is Channelized T1
Cablelength is long gain36 0db
Transmitter is sending remote alarm.
Receiver has loss of signal.
alarm-trigger is not set
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (387 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 387 Unavail Secs
Total Data (last 1 15 minute intervals):
0 Line Code Violations, 0 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
T1 2/1 is down.
Applique type is Channelized T1
Cablelength is long gain36 0db
Transmitter is sending remote alarm.
Receiver has loss of signal.
alarm-trigger is not set
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (387 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 387 Unavail Secs
Total Data (last 1 15 minute intervals):
0 Line Code Violations, 0 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
T1 2/2 is down.
Applique type is Channelized T1
Cablelength is long gain36 0db
Transmitter is sending remote alarm.
Receiver has loss of signal.
alarm-trigger is not set
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (387 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 387 Unavail Secs
Total Data (last 1 15 minute intervals):
0 Line Code Violations, 0 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
T1 2/3 is down.
Applique type is Channelized T1
Cablelength is long gain36 0db
Transmitter is sending remote alarm.
Receiver has loss of signal.
alarm-trigger is not set
Framing is ESF, Line Code is B8ZS, Clock Source is Line.
Data in current interval (387 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 387 Unavail Secs
Total Data (last 1 15 minute intervals):
0 Line Code Violations, 0 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 900 Unavail Secs
7204#
++ sho log +++
00:15:51: %OIR-6-REMCARD: Card removed from slot 2, interfaces disabled
00:15:53: %LINK-5-CHANGED: Interface 2/3, changed state to administratively
down
00:15:53: %LINK-5-CHANGED: Interface 2/2, changed state to administratively
down
00:15:53: %LINK-5-CHANGED: Interface 2/1, changed state to administratively
down
00:15:53: %LINK-5-CHANGED: Interface 2/0, changed state to administratively
down
00:16:06: %OIR-6-INSCARD: Card inserted in slot 2, interfaces administratively
s
hut down
Thank you in Advance,
David Cearlock
CCNP