From: Brian Dennis (bdennis@internetworkexpert.com)
Date: Sat Jul 24 2004 - 16:50:04 GMT-3
Sergio,
Without interesting traffic, R3 will drop all calls after 120
seconds.
In regards to dialer watch, the router with dialer watch
configured does not inform the remote router that is should not drop the
call. You do this manually when you enter the "dialer idle-timeout 0"
command on the router without dialer watch configured.
Brian Dennis, CCIE #2210 (R&S/ISP-Dial/Security)
bdennis@internetworkexpert.com
Internetwork Expert, Inc.
http://www.InternetworkExpert.com
Toll Free: 877-224-8987
Direct: 775-745-6404 (Outside the US and Canada)
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Sergio Jimenez Arguedas
Sent: Saturday, July 24, 2004 12:06 PM
To: ccielab@groupstudy.com
Subject: RV: PPP CALLBACK WITH DIALER-WATCH!!!
Hi Brain
Thanks for your help!!!