From: Aldo (febro@yahoo.com)
Date: Sat Aug 23 2003 - 04:33:29 GMT-3
Hi all,
I'm having problem with my Emutel Lite ISDN Simulator as the "P" led on
BRI-2 port does not lit up.
When I power cycle the box, all leds lit up for about 1 sec, the power led
stays on, and "OP" led is blinking red continuously (the manual says if OP
led is blinking it means the unit is functioning correctly).
I hooked up two 2503s, R1 to BRI-1, and R2 to BRI-2.
I just configured the bare minimum on both routers with "isdn switch-type
basic-dms100" command.
I see P led lit up on BRI-1, but not on BRI-2.
When I do a quick "show isdn status" command,
R1 says "Layer 1 Status: ACTIVE", R2 says "Layer 1 Status: DEACTIVATED".
When I swap ports (R1 to BRI-2, R2 to BRI-1),
R1 says "Layer 1 Status: DEACTIVATED", R2 says "Layer 1 Status: ACTIVE"
Am I missing something here on Emutel Lite or 2503 config?
or do I have faulty hardware on BRI-2 port?
Any input is appreciated. Thanks!
Aldo
--------------------------------
below is my Emutel Lite setting:
:: Hardware Setup
Coms Port Baud Rate 9600
Coms Port Parity None
Coms Port Stop Bits 1
Coms Port Data Bits 8
NT/Transparent Mode NT Mode
BRI1 Power Off
BRI2 Power Off
U Power Operation Normal
S Power Operation Normal
S Bus Timing Fixed
Selected Tone 1000Hz @ 0dB
BRI1/B1 Delay 0 ms
BRI1/B2 Delay 0 ms
:: Software Setup
Network Type NT DMS100
Drop Layer 2 if No Call Active Yes
Drop Layer 1 if Layer 2 Inactive No
Drop TEI if Layer 1 Inactive No
Point to multipoint configuration Enter
Service Profile IDs (SPIDs) Mandatory
Allow Overlap Sending/Receiving No
Numbering System Option 2 DN/2 SPID (Fixed B)
Called Party Number Yes
Calling Party Number Yes
Called Party Subaddressing No
Calling Party Subaddressing No
High Layer Compatibility No
Low Layer Compatibility No
D-Channel X25 Setup Yes
This archive was generated by hypermail 2.1.4 : Tue Sep 02 2003 - 18:54:05 GMT-3