RE: help pls

From: Adam Crisp (adam.crisp@totalise.co.uk)
Date: Fri Oct 25 2002 - 06:43:43 GMT-3


I know this sounds crazy,
but swap the DTE / DCE cable around, and run the clock from the other end.
I had have the same problem on some of my 2500's.
I think the clock drive circuitry can go bad after a while...

Adam

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com]On Behalf Of
aansar@sscomp.com.sg
Sent: 25 October 2002 09:25
To: ccielab@groupstudy.com
Subject: help pls

one of 2501 in my lab developed sudden problem
line protocol in both the serial interface is keep on going down and up ..
i checked everything everything is fine.. hardware is always up only line
protocol is thrashing. any idea .. anyone faced this problem before with
2501
i just configured clock and hdlc thats it ..
if any known bug pls let me know.. last thing should happen to me is that
router going dead.. oh no
thanks
aa



This archive was generated by hypermail 2.1.4 : Tue Nov 05 2002 - 08:35:56 GMT-3