From: Stephen C. Feldberg (scfeldberg@xxxxxxxxxxx)
Date: Tue Apr 30 2002 - 14:44:56 GMT-3
Yes I had an AGS+ with the same issues. If you ordered your cables with the
DCE end on the AGS side as I did you will need to move the jumpers on the
Serial controller cards. You will know that it is working correctly when
the DCE LED indicators illuminate on the Serial applique.
Steve
----- Original Message -----
From: <Ian.C.Stong@mail.sprint.com>
To: <ccielab@groupstudy.com>
Sent: Tuesday, April 30, 2002 7:31 AM
Subject: AGS+ Serial interfaces
> I have an AGS that I'm trying to use as a Frame Relay switch. None of
> the 10 serial interfaces will show up/up. They all show line up and
> protocol down. I even tried a point to point between AGS and 2501
> router using hdlc encapsulation and same affect. It's not a basic issue
> like clock rate, dte/dce etc.
>
> I found some Cisco documentation that talks about moving some jumpers
> around for dte versus dce.... Does anyone out there have an AGS and if
> so have you experienced a similar issue?
>
>
> Thanks,