Re: Catalyst 5000 via 2511

From: Erick B. (erickbe@xxxxxxxxx)
Date: Fri Feb 22 2002 - 17:07:43 GMT-3


   
Hi,

Put a 'no exec' under the line for the cat5000.

I'm betting that when you power them on together the
5000 sends signal out its port and the 2511
establishes a connection. If you a 'show line' on the
2511 then clear line 2 that should free up the
connection then you should be able to get to it. The
'no exec' prevents inbound traffic from using the
line.