From: Andrew Short (ashort@xxxxxxxxxxxxxxx)
Date: Mon Jan 29 2001 - 14:20:30 GMT-3
Pretty sure that you want to specify clock rate "line" for ONE of the
modules. You want ONE of the CSU/DSU modules to accept clocking from the
other.
On Mon, 29 Jan 2001, Tomohiro Yoshizawa wrote:
> Hi everyone!
> I have one 2524 and one 2525, each has only one 4-wire
> 56k CSU/DSU module. I want to conneto both two routers
> each other, so I used Cisco rolled RJ-45 cable to
> connet them. Then I input the following command at
> each routers.
> *************
> interface serial 0
> no shutdown
> ip address 200.1.1.1 / 200.1.1.2
> service-module 56k clock rate 56
> ***************************
> After I input these command, the line became up for a
> while. I checke "show ip route" and it showed the
> direct connection. But it changed to down in a few
> second. I don't know why. Could you give me some
> advice? Thanks.
>
> Tomohiro
>
This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:27:47 GMT-3