Re: Token Ring router

From: David M Anderson (dma@xxxxxxxxx)
Date: Wed Jan 17 2001 - 14:16:26 GMT-3


   
Did you try to reload the routers? It might allow them to reinsert into the ri
ng properly. Also, check your token ring interfaces on the router. Make sure
they are set for the same speed (ie 4mb, or 16mb) and that they are both functi
oning.
hope it helps
At 04:46 PM 01/17/2001 +0000, McCallum, Robert wrote:
>Hello,
>
>
>Trying to configure up a lab at the moment. I am running into severe
>difficulty when trying to connect two routers via a token ring interface.
>
>Scenario = R1 ---token ring0/0(ip 148.100.150.1/24) ---- MAU ----token
>ring0/0(ip 148.100.150.2/24) ----R2.
>
>I am getting all sorts of ring errors i.e. need to wait for new
>monitor.%TR-3-OPENFAIL: Unit 0, open failed: phase4, ring beaconing
>
>Whether I configure source bridge ring numbers makes no difference.
>
>Has anyone done this before who can point me to a link or in the right
>direction. Try not to tell me the answer right out.
>
>Cheers
>
>Robert McCallum
>



This archive was generated by hypermail 2.1.4 : Thu Jun 13 2002 - 10:27:32 GMT-3