Re: back to back frame-relay

From: Tony Singh <mothafungla_at_gmail.com>
Date: Thu, 27 Mar 2014 17:09:59 +0000

Andrew

So how is what you're saying different to what I suggested?

I said nothing of a serial cable

--
BR
Tony
> On 27 Mar 2014, at 16:16, "Andrew LaPorte" <andy_at_cloud9.net> wrote:
> 
> 
> 
> I think what you were looking for on your questions 
> 
> (on server side)
> frame-relay switching
> interface <x/x/x>
>    encap frame-relay
>    frame-relay intf-type DCE
> 
> (on client side)
> interface <x/x/x>
>    encap frame-relay
> 
> From there you may need frame-relay map statements if you are using the main
> interface or frame-relay interface-dlci if you are using a sub interface.
> 
> The DCE has nothing to do with the serial cable it has to do with who is
> controlling the frame-relay, i.e. keepalives which send LMI are active on
> the side that is frame-relay switching.  
> 
> Keep in mind the dlci used are normally the same but can be different on a
> main interface if you add an additional dummy map state with the other
> side's dcli.  
> 
> Andy
> 
> -----Original Message-----
> From: nobody_at_groupstudy.com [mailto:nobody_at_groupstudy.com] On Behalf Of Tony
> Singh
> Sent: Thursday, March 27, 2014 8:23 AM
> To: _ _
> Cc: Cisco certification
> Subject: Re: back to back frame-relay
> 
> 2.either way 
> 
> --
> BR
> 
> Tony
> 
>> On 27 Mar 2014, at 10:20, _ _ <krzysiek.zalewski_at_gmail.com> wrote:
>> 
>> Hi Tony
>> 1. clear
>> 2. it means I need inverse-arp enabled?
>> 
>>> On 3/27/14, Tony Singh <mothafungla_at_gmail.com> wrote:
>>> 
>>> two methods of achieving back to back frame relay
>>> 
>>> 1. Need to turn off keepalives both ends else L2 process fails (as 
>>> we're expecting LMI messages from provider) Or 2. Enable one end of 
>>> the link to be frame-relay DCE type and by enabling frame-relay PVC 
>>> switching on the same side (this simulates a DTE to DCE 
>>> physical peering for which frame-relay LMI messages will be sent and 
>>> received using default Cisco LMI type)
>>> 
>>> --
>>> BR
>>> 
>>> Tony
>>> 
>>>> On 27 Mar 2014, at 08:07, _ _ <krzysiek.zalewski_at_gmail.com> wrote:
>>>> 
>>>> Hi
>>>> 
>>>> It is possible create b2b fr link in which:
>>>> 
>>>>> keepalive must be on, and inverse-arp must be off
>>>> 
>>>> --
>>>> Krzysiek
>>>> 
>>>> 
>>>> Blogs and organic groups at http://www.ccie.net
>>>> 
>>>> ____________________________________________________________________
>>>> ___ Subscription information may be found at:
>>>> http://www.groupstudy.com/list/CCIELab.html
>> 
>> 
>> --
>> Krzysiek
> 
> 
> Blogs and organic groups at http://www.ccie.net
> 
> _______________________________________________________________________
> Subscription information may be found at: 
> http://www.groupstudy.com/list/CCIELab.html
Blogs and organic groups at http://www.ccie.net
Received on Thu Mar 27 2014 - 17:09:59 ART

This archive was generated by hypermail 2.2.0 : Thu Apr 03 2014 - 17:12:31 ART