Re: dynamips c3640 trunk problem nm-16esw

From: Ivan Hrvatska <ivanzghr_at_gmail.com>
Date: Sat, 19 May 2012 12:10:28 +0200

Yes, it works fine with just one module, but it is very limited with
features. You cannot do most of the L2 labs, specially mls qos labs.

On Thu, May 17, 2012 at 7:34 AM, shekhar sharma
<shekhar.sharma21_at_gmail.com> wrote:
> Hi Ivan,
>
> Any router with 2 nm-15esw module doesn't work with gns3. It works with only
> single Nm-15esw module. I have also tried it multiple times before .But it
> doesn't work. It is a bug in GNS3. It doesn't support 2 esw module.
>
> and yes you are right, configution will be fine, trunk links and access
> ports links will be fine , But you will not be able to ping .
>
> Try connecting only single module , it will work 100%.
>
> Regards,
> Shekhar
>
> On Thu, May 17, 2012 at 4:10 AM, Ivan Hrvatska <ivanzghr_at_gmail.com> wrote:
>>
>> Hi,
>>
>> I'm using c3640 with nm-16esw in dynamips as cat switch. If I have two
>> 16esw modules in every 3640, one module has connected routers and the
>> other
>> is used for interconnection between switches. Problem is that R1,
>> connected
>> to Cat2, cannot ping BB1, connected to Cat1. Between switches dot1q trunk.
>> Even configuration is good, ping failes. Same thing with c3725.
>> When I use just one nm-16esw, where trunk between switches is together
>> with
>> connected routers on the same module, it works fine. Is there any catch
>> with 2 modules since it doesn't not work? Thanks for help.
>>
>> Regards
>>
>>
>> Blogs and organic groups at http://www.ccie.net
>>
>> _______________________________________________________________________
>> Subscription information may be found at:
>> http://www.groupstudy.com/list/CCIELab.html

Blogs and organic groups at http://www.ccie.net
Received on Sat May 19 2012 - 12:10:28 ART