Re: OT:Tengig Ports not connected error

From: N. Max Pierson <nmaxpierson_at_gmail.com>
Date: Sun, 22 Jan 2012 10:37:06 -0600

Hi Faizan,

Have you configured the module to support 1g instead of 10g (10g is the
default)???

http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/12.2/46sg/configuration/guide/sw_int.html#wp1077316

HTH's,

max

On Sun, Jan 22, 2012 at 6:14 AM, faizan khurshid <
faizankhurshid921_at_hotmail.com> wrote:

> Hi Experts
>
> I have one Core WS-C4510R-E with WS-X45-SUP6-E .Im geeting following
> error
> once i reboot my Switch .A device can detect 10G ports but status remain
> down
> even using no shut commands
>
> I have TwinTenGig Converter installed on Core Switch
>
>
> C4K_GLMMAN-3-X2PLUGGABLESEEPROMREADFAILED:
> Failed to read seeprom on port Te2/8. Reinsert X2 module or configure
> GigabitEthernet port group if TwinGigConverter is installed.
>
>
> Any suggestion help will be highly appreciated
>
>
> Regards
>
> Faizan Khurshid
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html

Blogs and organic groups at http://www.ccie.net