Gooday
I have a question I wish to check with you experts. Have 2 routers directly
connected. What could cause the hold-timer to jump way above the maximum
Lets say my hello timer is set 3s and holding multiplier to 4 . So holding
timer =4x3=12s
config
R1
interface POS1/0/0
ip router isis 1
ip a ddress w.x.y.z 255.255.255.254
encapsulation ppp
isis circuit-type level-2-only
isis hello-multiplier 4
isis hello-interval 3
!
R2
interface POS1/0/0
ip router isis 1
ip a ddress w.x.y.z+1 255.255.255.254
encapsulation ppp
isis circuit-type level-2-only
isis hello-multiplier 4
isis hello-interval 3
!
If i check from R2
R1#sh isis neighbors
System Id Type Interface IP Address State Holdtime Circuit Id
R2 L2 PO1/0/0 w.x.y.z+1 UP
299 02
Regards
Blogs and organic groups at http://www.ccie.net
Received on Tue Apr 12 2011 - 23:40:33 ART