ISIS hello timers

From: Edmore Chingwena <chingwenaed_at_gmail.com>
Date: Tue, 12 Apr 2011 23:40:33 +0200

Gooday

I have a question I wish to check with you experts. Have 2 routers directly
connected. What could cause the hold-timer to jump way above the maximum

Lets say my hello timer is set 3s and holding multiplier to 4 . So holding
timer =4x3=12s

config

R1

interface POS1/0/0
ip router isis 1
 ip a ddress w.x.y.z 255.255.255.254
 encapsulation ppp
  isis circuit-type level-2-only
 isis hello-multiplier 4
 isis hello-interval 3
!

R2

 interface POS1/0/0
ip router isis 1
  ip a ddress w.x.y.z+1 255.255.255.254
 encapsulation ppp
  isis circuit-type level-2-only
 isis hello-multiplier 4
 isis hello-interval 3
!

If i check from R2

R1#sh isis neighbors

System Id Type Interface IP Address State Holdtime Circuit Id
R2 L2 PO1/0/0 w.x.y.z+1 UP
299 02
Regards

Blogs and organic groups at http://www.ccie.net
Received on Tue Apr 12 2011 - 23:40:33 ART