got it, thanks guys its a bug in the ios, so I have to change to ios
thanks :-)
On Sun, May 9, 2010 at 7:07 PM, Salah ElShekeil
<salah.elshekeil_at_gmail.com>wrote:
> Hi all,
>
> I have 2 E6509-V-E, connected togather below is the configuration
>
> SW 1:
>
> switch virtual domain 50
> switch 1
> switch 1 priority 150
> switch 1 preempt
>
> interface port-channel 10
> switch virtual link 1
> no shutdown
>
> interface range tengigabitethernet 1/8
> channel-group 10 mode on
> no shutdown
>
> interface range tengigabitethernet 5/4
> channel-group 10 mode on
> no shutdown
>
> SW 2
>
> switch virtual domain 50
> switch 2
>
> interface port-channel 20
> switch virtual link 2
> no shutdown
>
> interface range tengigabitethernet 1/8
> channel-group 20 mode on
> no shutdown
>
> interface range tengigabitethernet 5/4
> channel-group 20 mode on
> no shutdown
> when I convert it to virtual mode it reloads then I'm getting this error
>
> %VSL_BRINGUP-3-MODULE_DOWN: Failed to bring up VSL module in slot 5 switch
> 1. Not enough power.
>
> and it reload again!! any advice?
>
> Thanks
>
> SE
>
>
>
>
-- Salah CCIE #24207 Blogs and organic groups at http://www.ccie.netReceived on Sun May 09 2010 - 19:23:54 ART