VSS Problem

From: Salah ElShekeil <salah.elshekeil_at_gmail.com>
Date: Sun, 9 May 2010 19:07:36 +0300

Hi all,

I have 2 E6509-V-E, connected togather below is the configuration

SW 1:

switch virtual domain 50
switch 1
switch 1 priority 150
switch 1 preempt

interface port-channel 10
switch virtual link 1
no shutdown

interface range tengigabitethernet 1/8
channel-group 10 mode on
no shutdown

interface range tengigabitethernet 5/4
channel-group 10 mode on
no shutdown

SW 2

switch virtual domain 50
switch 2

interface port-channel 20
switch virtual link 2
no shutdown

interface range tengigabitethernet 1/8
channel-group 20 mode on
no shutdown

interface range tengigabitethernet 5/4
channel-group 20 mode on
no shutdown
when I convert it to virtual mode it reloads then I'm getting this error

%VSL_BRINGUP-3-MODULE_DOWN: Failed to bring up VSL module in slot 5 switch
1. Not enough power.

and it reload again!! any advice?

Thanks

SE