Hi all,
I have 2 E6509-V-E, connected togather below is the configuration
SW 1:
switch virtual domain 50
switch 1
switch 1 priority 150
switch 1 preempt
interface port-channel 10
switch virtual link 1
no shutdown
interface range tengigabitethernet 1/8
channel-group 10 mode on
no shutdown
interface range tengigabitethernet 5/4
channel-group 10 mode on
no shutdown
SW 2
switch virtual domain 50
switch 2
interface port-channel 20
switch virtual link 2
no shutdown
interface range tengigabitethernet 1/8
channel-group 20 mode on
no shutdown
interface range tengigabitethernet 5/4
channel-group 20 mode on
no shutdown
when I convert it to virtual mode it reloads then I'm getting this error
%VSL_BRINGUP-3-MODULE_DOWN: Failed to bring up VSL module in slot 5 switch
1. Not enough power.
and it reload again!! any advice?
Thanks
SE
Blogs and organic groups at http://www.ccie.net
Received on Sun May 09 2010 - 19:07:36 ART
This archive was generated by hypermail 2.2.0 : Tue Jun 01 2010 - 07:09:52 ART