Re: Need a new terminal server, the old one seems to be broken.

From: Hans Eriksson <eriksson.hans_at_gmail.com>
Date: Fri, 30 Apr 2010 02:28:48 +0200

Yes, I have a 3640. this was the router I did have the module in, that was
broken.
So I am googling and looking around the net for either a NM16,NM32 or 2511.
The one i find to the best price ASAP.
Thanks for all the answers.

2010/4/30 Narbik Kocharians <narbikk_at_gmail.com>

> Kambiz,
> I agree with you, if you get a 3640, you can use an NM-16a and couple of
> octal cables and use them as your access-server, this can be in one of the
> slots, and your Frame-relay switching can be handled with one NM-8A/s in the
> second slot and a Fastethernet module to your home router, all in one. less
> utility bill.
>
> On Thu, Apr 29, 2010 at 4:56 PM, Hans Eriksson <eriksson.hans_at_gmail.com>wrote:
>
>> It was my NM-32A that are broken. So I am trying to find either a used
>> NM-32A
>> or a used 2511. The good thing is if
>> I get a used NM-32A i have the octa-cables.
>>
>> 2010/4/30 Kambiz Agahian <kagahian_at_ccbootcamp.com>
>>
>> > Hans,
>> >
>> > If you have a (NM) modular router you might wish to consider an NM
>> > module for instance in a 3640. Of course if you do have one of those
>> > routers you can also save some rack space and be green :) .
>> >
>> > In most countries at the same price you can go for some used 2500 guys
>> > with Octal cables (a real mess) or even 2500-RJ without octal cables
>> > (this one is usually pricey). For a home rack I'd purchase a used
>> > 2511-RJ; it gives you a nice and neat rack.
>> >
>> >
>> http://www.cisco.com/en/US/i/000001-100000/10001-15000/14001-14500/14479
>> > .jpg
>> >
>> > --------------------------
>> > Kambiz Agahian
>> > CCIE (R&S)
>> > CCSI, WAASSE, RSSSE
>> > Technical Instructor
>> > CCBOOTCAMP - Cisco Learning Solutions Partner (CLSP)
>> > Email: kagahian_at_ccbootcamp.com
>> > Toll Free: 877-654-2243
>> > International: +1-702-968-5100
>> > Skype: skype:ccbootcamp?call
>> > FAX: +1-702-446-8012
>> > YES! We take Cisco Learning Credits!
>> > Training And Remote Racks: http://www.ccbootcamp.com
>> > OEQ Voice Waiver: http://www.ccbootcamp.com/noeqvoice.html
>> > OEQ R&S Waiver: http://www.ccbootcamp.com/noeqrs.html
>> > OEQ Commercial: http://www.ccbootcamp.com/noeq.mpg
>> >
>> >
>> >
>> >
>> >
>> > -----Original Message-----
>> > From: nobody_at_groupstudy.com [mailto:nobody_at_groupstudy.com] On Behalf Of
>> > Hans Eriksson
>> > Sent: Thursday, April 29, 2010 4:27 PM
>> > To: ccielab_at_groupstudy.com
>> > Subject: Re: Need a new terminal server, the old one seems to be broken.
>> > Any suggestions anyone?
>> >
>> > I will try to find some used 2511, I hope some one in Sweden have those
>> > for
>> > sale, or else I wll use ebay.
>> > Thanks.
>> >
>> > 2010/4/30 Joe Astorino <jastorino_at_ipexpert.com>
>> >
>> > > The 2511 is great
>> > >
>> > >
>> > > Sent from my Verizon Wireless BlackBerry
>> > >
>> > > Regards,
>> > >
>> > > Joe Astorino - CCIE #24347
>> > > Sr. Technical Instructor - IPexpert
>> > > Mailto: jastorino_at_ipexpert.com
>> > > Telephone: +1.810.326.1444
>> > > Live Assistance, Please visit: www.ipexpert.com/chat
>> > > eFax: +1.810.454.0130
>> > >
>> > > IPexpert is a premier provider of Self-Study Workbooks, Video on
>> > Demand,
>> > > Audio Tools, Online Hardware Rental and Classroom Training for the
>> > Cisco
>> > > CCIE (R&S, Voice, Security & Service Provider) certification(s) with
>> > > training locations throughout the United States, Europe, South Asia
>> > and
>> > > Australia. Be sure to visit our online communities at
>> > > www.ipexpert.com/communities and our public website at
>> > www.ipexpert.com
>> > >
>> > > -----Original Message-----
>> > > From: John Lockie <john.lockie_at_gmail.com>
>> > > Date: Thu, 29 Apr 2010 16:07:17
>> > > To: Hans Eriksson<eriksson.hans_at_gmail.com>; <ccielab_at_groupstudy.com>
>> > > Subject: Re: Need a new terminal server, the old one seems to be
>> > broken.
>> > > Any suggestions anyone?
>> > >
>> > > Have you considered 2511? :)
>> > >
>> > >
>> > > On 4/29/10 2:53 PM, "Hans Eriksson" <eriksson.hans_at_gmail.com> wrote:
>> > >
>> > > > Need a new terminal server, the old one seems to be broken. Any
>> > > suggestions
>> > > > anyone?
>> > > >
>> > > >
>> > > >
>> > > > My terminal server seems to bee broken, I have tried different IOS
>> > and
>> > > > different chassi. I still have the same error. I have tried
>> > different
>> > > > configurations. But the same error seems to haunting me.
>> > > >
>> > > >
>> > > >
>> > > > So I would need a new terminal server, that don t set me back too
>> > many
>> > > $$$.
>> > > > Any ides anyone.
>> > > >
>> > > > I am no config ace when we talk about terminal server.
>> > > > This is what I have be using. I have tried 3620 and 3640 plus
>> > diffrent
>> > > > slots.
>> > > >
>> > > >
>> > ------------------------------------------------------------------------
>> > > > Have tried diffrent configs.
>> > > >
>> > > > *Standard*
>> > > > !
>> > > > line con 0
>> > > > login local
>> > > > line 65 96
>> > > > line aux 0
>> > > > line vty 0 4
>> > > > access-class 1 in
>> > > > login local
>> > > > !
>> > > > *some other config*
>> > > > !
>> > > > line 65 96
>> > > > transport preferred telnet
>> > > > transport input telnet
>> > > > stopbits 1
>> > > > flowcontrol hardware
>> > > > !
>> > > >
>> > > >
>> > ------------------------------------------------------------------------
>> > -
>> > > > error
>> > > >
>> > ------------------------------------------------------------------------
>> > -
>> > > >
>> > > > Log Buffer (4096 bytes):
>> > > > r is not responding, power cycle the router
>> > > > 00:01:38: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller is not
>> > > responding,
>> > > > power cycle the router
>> > > > 00:01:41: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller is not
>> > > responding,
>> > > > power cycle the router
>> > > > 00:01:44: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller is not
>> > > responding,
>> > > > power cycle the router
>> > > > 00:01:47: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller is not
>> > > responding,
>> > > > power cycle the router
>> > > > 00:01:50: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller is not
>> > > responding,
>> > > > power cycle the router
>> > > > 00:01:51: %LINK-3-UPDOWN: Interface FastEthernet0/0, changed state
>> > to up
>> > > > *Mar 1 02:04:03.815: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:06.815: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:09.815: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:12.815: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:15.815: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:18.815: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:21.815: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:24.815: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:24.827: %SYS-3-CPUHOG: Task ran for 24024 msec (0/0),
>> > > process
>> > > > = Exec, PC = 602F0CD0.
>> > > > -Traceback= 602F0CD8 602F1518 602F13E8 60312700 603767D4 603767C0
>> > > > *Mar 1 02:04:45.923: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:48.923: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:51.923: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:54.923: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:04:54.923: %SYS-3-CPUHOG: Task ran for 12000 msec (0/0),
>> > > process
>> > > > = Exec, PC = 602CC4E0.
>> > > > -Traceback= 602CC4E8 60192868 6032805C 60304554 60312758 603767D4
>> > > 603767C0
>> > > > *Mar 1 02:05:07.923: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:05:10.923: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:05:10.923: %SYS-3-CPUHOG: Task ran for 6000 msec (1/1),
>> > > process =
>> > > > Exec, PC = 602CC4E0.
>> > > > -Traceback= 602CC4E8 60192868 6032805C 60304554 60312758 603767D4
>> > > 603767C0
>> > > > *Mar 1 02:05:23.923: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:05:26.923: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:05:26.931: %SYS-3-CPUHOG: Task ran for 6008 msec (0/0),
>> > > process =
>> > > > Exec, PC = 602CC4E0.
>> > > > -Traceback= 602CC4E8 60192868 6032805C 60304554 60312758 603767D4
>> > > 603767C0
>> > > > *Mar 1 02:08:28.823: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:08:31.823: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:08:34.823: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:08:37.823: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:08:40.823: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:08:43.823: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:08:46.823: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:08:49.823: %CIRRUS-3-HWNORESPONSE: The CD2430 Controller
>> > is
>> > > not
>> > > > responding, power cycle the router
>> > > > *Mar 1 02:08:49.835: %SYS-3-CPUHOG: Task ran for 24024 msec (1/1),
>> > > process
>> > > > = Exec, PC = 602F0CD0.
>> > > > -Traceback= 602F0CD8 602F1518 602F13E8 60312700 603767D4 603767C0
>> > > >
>> > > >
>> > > > Blogs and organic groups at http://www.ccie.net
>> > > >
>> > > >
>> > _______________________________________________________________________
>> > > > Subscription information may be found at:
>> > > > http://www.groupstudy.com/list/CCIELab.html
>> > >
>> > >
>> > > Blogs and organic groups at http://www.ccie.net
>> > >
>> > >
>> > _______________________________________________________________________
>> > > Subscription information may be found at:
>> > > http://www.groupstudy.com/list/CCIELab.html
>> >
>> >
>> > Blogs and organic groups at http://www.ccie.net
>> >
>> > _______________________________________________________________________
>> > Subscription information may be found at:
>> > http://www.groupstudy.com/list/CCIELab.html
>>
>>
>> Blogs and organic groups at http://www.ccie.net
>>
>> _______________________________________________________________________
>> Subscription information may be found at:
>> http://www.groupstudy.com/list/CCIELab.html
>>
>>
>>
>>
>>
>>
>>
>>
>
>
> --
> Narbik Kocharians
> CCSI#30832, CCIE# 12410 (R&S, SP, Security)
> www.MicronicsTraining.com
> Sr. Technical Instructor
>
> YES! We take Cisco Learning Credits!
> Training And Remote Racks available

Blogs and organic groups at http://www.ccie.net
Received on Fri Apr 30 2010 - 02:28:48 ART

This archive was generated by hypermail 2.2.0 : Sat May 01 2010 - 09:49:57 ART