Re: IDSM failed SCP download

From: Carlos G Mendioroz <tron_at_huapi.ba.ar>
Date: Wed, 09 Dec 2009 08:04:03 -0300

I've seen that on a fried 6748:

00:05:37: %ONLINE-SP-6-TIMER: Module 1, Proc. 0. Failed to bring online
because of timer event
00:05:37: %C6KPWR-SP-4-DISABLED: power to module in slot 1 set off
(Module Failed SCP dnld)

I guess that it's hardware issue. I second the "try another slot"
advice (only if you are in a lab environment), or else, RMA it.

-Carlos

Mahmoud Genidy @ 8/12/2009 19:18 -0300 dixit:
> Hi experts,
>
> I have IDSM on Cat6500 failed to work with this error message:
>
> [ %C6KPWR-SP-4-DISABLED: power to module in slot 5 set off (Module Failed
> SCP dnld) ]
>
> Any idea why this is happening or how to solve it?
>
> I have searched Cisco website and found that message listed with the advice
> of resetting the module hopefully it will work!
> I did resetting the module and the Cat6500 switch and the problem still
> exist.
>
> Thanks,
> Mahmoud Genidy
> CCIE#23690
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>

-- 
Carlos G Mendioroz  <tron_at_huapi.ba.ar>  LW7 EQI  Argentina
Blogs and organic groups at http://www.ccie.net
Received on Wed Dec 09 2009 - 08:04:03 ART