I know this isn't really the list to discuss dynamips but I have already
been through the hacki and other forums but couldn't find the required info.
I have managed to obtain some 3750s and 3560s at my workplace but am unable
to integrate them with my server running dynamips. I have windows 2000
server running on this box and I can't move to linux due to some
administrative reasons at work. I tried a lot of options but none of them
worked and am now stuck up at a situation wherein the moment I connect the
server's NIC to the breakout switch, the server crashes. Has someone been
successfully able to integrate dynamips with real switches on a windows box
. I would like to understand how the physical connections are ( I have a
feeling that I am not doing it right ) . Here is an excerpt from my net file
config .
[[Router R1]]
model = 3640
console = 2003
autostart = False
slot0 = NM-1FE-TX
F0/0 = SW1 1
[[Router R2]]
model = 3640
console = 2004
autostart = False
slot0 = NM-1FE-TX
F0/0 = SW1 2
[[ETHSW SW1]]
1 = access 101
2 = access 102
15 = dot1q 1
NIO_gen_eth:\Device\NPF_{243BAEEE-213F-44D2-9F8E-59D0C9EC23A1}
My PC's NIC goes to a 2950 f0/19 which is configured as a trunk. F0/1 and
F0/2 in this 2950 are access ports in VLAN 101 and 102 respectively. These
then connect to a 3750 g1/0/1 and g1/0/2 both of which are access ports in
VLAN 10. I am not able to ping b/w R1 and R2.
Thanks in anticipation
Ravi
Blogs and organic groups at http://www.ccie.net
Received on Tue Sep 15 2009 - 15:13:42 ART