do a "show system mtu" and you may find your problem.
On Mon, Apr 6, 2009 at 5:14 AM, Modular <modulartx_at_gmail.com> wrote:
> Does anyone know if there's a common problem with running EIGRP between Cat
> 3550/3560 switches??
> It seems like every time I set up EIGRP between my switches I have this
> issue where the adjacency goes
> up and down.... as if he hold-timer expires. But, right after it goes down
> it comes back up. I've tried
> increasing the hello & hold timers but that hasn't worked. I'll paste the
> message below:
>
> Cat4#
> *Mar 1 04:00:31.695: %DUAL-5-NBRCHANGE: EIGRP-IPv4:(134) 134: Neighbor
> 148.48.114.101 (Vlan114) is down: retry limit exceeded
> Cat4#
> *Mar 1 04:00:46.359: %DUAL-5-NBRCHANGE: EIGRP-IPv4:(134) 134: Neighbor
> 148.48.114.101 (Vlan114) is up: new adjacency
> Cat4#
> *Mar 1 04:02:50.870: %DUAL-5-NBRCHANGE: EIGRP-IPv4:(134) 134: Neighbor
> 148.48.114.101 (Vlan114) is down: retry limit exceeded
> Cat4#
>
>
> Thanks,
> Bryan R.
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>
>
>
>
>
>
>
>
-- Pavel Bykov ---------------- Don't forget to help stopping the braindumps, use of which reduces value of your certifications. Sign the petition at http://www.stopbraindumps.com/ Blogs and organic groups at http://www.ccie.netReceived on Mon Apr 06 2009 - 09:52:14 ART