Re: Frame Relay not working --- DTE V.35 clocks stopped

From: Divin Mathew John <divinjohn_at_gmail.com>
Date: Sun, 5 Apr 2009 19:00:14 +0530

Did you try giving no shut. usually if u dont give no shut both line
and protocol will be down.! but if u forgot the clock rate 64000 then
protocol would be down.! physical connectivity will be UP.! and check
whether on both sides of the link.! encapsulation frame-relay is
given..
Thanking You

Yours Sincerely

Divin Mathew John
divinjohn_at_gmail.com
divin_at_dide3d.com
+91 9945430983
+91 9846697191
+974 5008916
PGP PUBLIC KEY BLOCK @ http://www.dide3d.com/divin_Public_PGP_key.txt

On Sun, Apr 5, 2009 at 6:54 PM, Thameem Maranveetil Parambath
<tparamba_at_thecontactcentre.ae> wrote:
> Can someone help me in this please.
>
> I have rented remote lab. On R3 and R5 I am trying to configure frame
> relay. But
>
> sh ip int br shows s0/0 as down , down
>
> sh controllers s0/0 is saying DTE V.35 clocks stopped.
>
> Why this should happen? Is it because the DCE is not configured with clock
> rate?
>
> Warm Regards
> Thameem
>
>
>
> -----------------------------------------
> The content of this email together with any attachments, statements
> and opinions expressed herein contains information that is private
> and confidential, are intended for the named addressee/s only. If
> you are not the addressee of this email you may not copy, forward,
> disclose or otherwise use it or any part of it in any form
> whatsoever. If you have received this message in error, please
> notify postmaster_at_etisalat.ae by email immediately and delete the
> message without making any copies.
>
>
> Blogs and organic groups at http://www.ccie.net
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html

Blogs and organic groups at http://www.ccie.net
Received on Sun Apr 05 2009 - 19:00:14 ART

This archive was generated by hypermail 2.2.0 : Mon May 04 2009 - 07:39:11 ART