From: Howard Hooper (Howard.Hooper@dupre.co.uk)
Date: Mon Nov 10 2008 - 10:19:24 ARST
Hi Reza,
That's great thank you for your advice, I thought to be on the safe side
I'll use classes for everything on the 3550 instead of using the
class-default from now on.
Also congratulations on passing recently that's excellent news!!
Kind regards
Howard
-----Original Message-----
From: Reza Toghraee [mailto:reza@toghraee.com]
Sent: 10 November 2008 12:05
To: Howard Hooper; ccielab@groupstudy.com
Subject: RE: Catalyst 3550 class-default
Howard,
Exactly same experience like me.
Only on 3560, you can use class-default. For 3550 you must create
classes to
match all other traffic.
Reza
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Howard Hooper
Sent: Monday, November 10, 2008 12:05 AM
To: ccielab@groupstudy.com
Subject: Re: Catalyst 3550 class-default
Hi All,
I was wondering if anybody could offer some advice on whether or not to
use
the class-default class on the 3550 if I come up against the need to in
the
lab?
The reason I ask is because I've seen it written in a few places that
using
the 3550 class-default class to match the remaining layer 2 or 3 traffic
is
a
hit and miss on whether or not it will work correctly.
A few weeks ago I was marked down in a Mock lab for using the class to
match
all remaining traffic....but then it was shown as being used in the
solution
for the question? :o)
Would you recommend using class-default or would you go for what seems
to be
the safest option of seperate classes for layer 3 and layer 2 matching
their
acl's (IP and mac matching any any or 0x0 0xFFFF) in my policy map?
Thank you in advance for any help you can offer on this
Howard
CONFIDENTIALITY NOTICE:
This e-mail (and any attachments) are confidential, legally privileged
and/or
protected by copyright. This e-mail is intended only for the addressee
or
the
person responsible for delivering it to the addressee. If you receive
this
e-mail in error please notify the sender by replying by e-mail or
telephone
immediately (telephone 01635 55 55 55. If calling from outside the UK
0044
1635 55 55 55) and then delete this e-mail (and any attachments) from
your
system, entirely. You should not disclose the contents of this e-mail
(and
any
attachments) to any other person and no copies should be made.
Company registration number: 1520800
Registered Office: du Pri plc, Vo-Tec Centre, Hambridge Lane, Newbury,
Berkshire. RG14 5TN.
Blogs and organic groups at http://www.ccie.net
This archive was generated by hypermail 2.1.4 : Mon Dec 01 2008 - 08:18:30 ARST