3750 upgrade with overwrite

From: Ram Shummoogum (rshummoo@ca.ibm.com)
Date: Wed Jul 23 2008 - 09:05:24 ART


As per the doc the overwrite is supposed to cleanup the old bin prior to
extracting but does not seem to be the case as shown below:
I had to manually delete the old bin.
Comments/???

archive download-sw /overwrite /allow-feature-upgrade
tftp://10.10.10.1/c3750-ipservicesk9-tar.122-25.SEE4.tar

examining image...
extracting info (111 bytes)
extracting c3750-ipservicesk9-mz.122-25.SEE4/info (700 bytes)
extracting info (111 bytes)

Stacking Version Number: 1.14

System Type: 0x00000000
  Ios Image File Size: 0x007AD200
  Total Image File Size: 0x009EC200
  Minimum Dram required: 0x08000000
  Image Suffix: ipservicesk9-122-25.SEE4
  Image Directory: c3750-ipservicesk9-mz.122-25.SEE4
  Image Name: c3750-ipservicesk9-mz.122-25.SEE4.bin
  Image Feature: IP|LAYER_3|PLUS|SSH|3DES|MIN_DRAM_MEG=128

Error: There is insufficient space in flash: to install the required
Error: image. Clean up some old images, and try again.

Switch#dir

RAM