Re: changing a subint type

From: Eric Phillips (eric@phillips.tc)
Date: Fri Jan 11 2008 - 17:15:45 ARST


Navid,

You likely need to reload, changing subinterface types or moving DLCIs often
requires you to reload.

We had a discussion a while ago and theorized all kinds of ways to keep that
from happening, but that did not work and we always had to reload the
router.

-Eric

On 1/10/08, Navid Daghighi <smart4D@free.fr> wrote:
>
> Hi,
>
> I typed "interface s0/0.1 multi-point"
>
> I need to change this into "point-to-point"
>
> when i do "no int s0/0.1" and "int s0/0.1 point", it keeps the subtype
> and refuse to change the link type
>
> what is the solution ?
>
> thanks,
> Navid
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
>

-- 
Eric M. Phillips                               Senior Network Consultant

LTI Information Technology http://www.ltiit.com 501 Avis Drive Ann Arbor, MI 48108

Phone: (734) 929-1400 Fax: (734) 929-1401



This archive was generated by hypermail 2.1.4 : Fri Feb 01 2008 - 10:37:59 ARST