From: Bit Gossip (bit.gossip@chello.nl)
Date: Fri Sep 07 2007 - 08:04:27 ART
Experts,
I think this could be possible somehow but I've become quite rusty with DDR
R4 and R5 are connected back-to-back with HDLC encapsulation
That would be nice and easy, but I am not allowed to assign the IP address
directly to the serial interface nor change interface encapsulation.
I was thinking to associate them with a dialer interface and this is as far as
I could go ....
Please help!
Bit
R5
interface Serial0/1
no ip address
dialer in-band
dialer pool-member 1
clock rate 128000
pulse-time 1
!
interface Dialer1
ip address 145.3.45.5 255.255.255.0
dialer pool 1
dialer-group 1
!
dialer-list 1 protocol ip permit
!
R5#ping 145.3.45.4
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echos to 145.3.45.4, timeout is 2 seconds:
*Mar 1 03:17:21.607: Di1 DDR: Cannot place call, no dialer string set.