Re: weird PIX 515E v 7.2.2 behavior

From: Farrukh Haroon (farrukhharoon@gmail.com)
Date: Wed May 09 2007 - 08:46:25 ART


This is the CSCsg87808 Bug
Use the 'Bug Toolkit' to search for it

CCO:

*Symptom:*
If snmp-server commands are configured, in a rare corner case
the configuration might fail to save to flash and give the error like below:

pix# wr mem
Cryptochecksum: ee8f5816 e1ce1ad7 83151424 f1a3b6fc %Error
reading system:/running-config (Configuration line too long)
Error executing command [FAILED]

*Conditions:*
The firewall must have snmp-server commands configured and running
version 7.2(1)25 or greater (includes 7.2(2)).

*Workaround:*
Remove the snmp-server commands from the configuration
-or-
downgrade to a version of code previous to 7.2(1)25

HTH

Farrukh

On 5/9/07, Alexei Monastyrnyi <alexeim@orcsoftware.com> wrote:
>
> Hi List.
>
> Just wanted to ask if someone has ever come across such.
>
> pix(config)# wr me
> Building configuration...
> Cryptochecksum: 3f902968 e384da03 b938eff6 1bf4fb4f
>
> %Error reading system:/running-config (Configuration line too long)
> Error executing command
> [FAILED]
> pix(config)# copy run start
>
> Source filename [running-config]?
> Cryptochecksum: 3f902968 e384da03 b938eff6 1bf4fb4f
>
> %Error reading system:/running-config (Configuration line too long)
>
> Problem appeared after upgrading to 7.2.2 on my failover pair of PIXes.
> System can read and save running config on stanalone PIX 515 with 7.2.2
> in another location just fine.
>
> Workaround so far is to save running-config with help of terminal
> logging and then pick it to startup-config via TFTP.
>
> Any hint would be highly appreciated.
>
> A.
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html



This archive was generated by hypermail 2.1.4 : Fri Jun 01 2007 - 06:55:20 ART