RE: Frame relay back to back

From: Scott Morris (smorris@ipexpert.com)
Date: Sat Apr 28 2007 - 14:01:46 ART


"no keepalive" will stop the search for LMI.... Right now, you are looking
for a frame switch to respond to you and that's not happening.

HTH,

 
Scott Morris, CCIE4 (R&S/ISP-Dial/Security/Service Provider) #4713, JNCIE
#153, CISSP, et al.
CCSI/JNCI-M/JNCI-J
IPexpert VP - Curriculum Development
IPexpert Sr. Technical Instructor
smorris@ipexpert.com
http://www.ipexpert.com
 
 

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
premkumar somasundaram
Sent: Saturday, April 28, 2007 12:24 PM
To: ccielab@groupstudy.com
Subject: Frame relay back to back

Group ,
When I am configuring frame relay back to back over the serial connection,
the link stays up for 30 odd seconds and it goes down. R4 & R5 are
connected via serial link and I would like to configure frame relay back to
back over that . Here is the configuration....

R4

interface Serial2/1
 no ip address
 encapsulation frame-relay
!
interface Serial2/1.1 point-to-point
 ip address 145.1.45.4 255.255.255.0
 frame-relay interface-dlci 111

R5
interface Serial2/1
 no ip address
 encapsulation frame-relay
 clock rate 64000
 no dce-terminal-timing-enable
!
interface Serial2/1.1 point-to-point
 ip address 145.1.45.5 255.255.255.0
 frame-relay interface-dlci 111

Am I missing some thing here..

Thanks in advance.
prem