From: Scott Morris (smorris@ipexpert.com)
Date: Sat Apr 28 2007 - 14:01:46 ART
"no keepalive" will stop the search for LMI.... Right now, you are looking
for a frame switch to respond to you and that's not happening.
HTH,
Scott Morris, CCIE4 (R&S/ISP-Dial/Security/Service Provider) #4713, JNCIE
#153, CISSP, et al.
CCSI/JNCI-M/JNCI-J
IPexpert VP - Curriculum Development
IPexpert Sr. Technical Instructor
smorris@ipexpert.com
http://www.ipexpert.com
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
premkumar somasundaram
Sent: Saturday, April 28, 2007 12:24 PM
To: ccielab@groupstudy.com
Subject: Frame relay back to back
Group ,
When I am configuring frame relay back to back over the serial connection,
the link stays up for 30 odd seconds and it goes down. R4 & R5 are
connected via serial link and I would like to configure frame relay back to
back over that . Here is the configuration....
R4
interface Serial2/1
no ip address
encapsulation frame-relay
!
interface Serial2/1.1 point-to-point
ip address 145.1.45.4 255.255.255.0
frame-relay interface-dlci 111
R5
interface Serial2/1
no ip address
encapsulation frame-relay
clock rate 64000
no dce-terminal-timing-enable
!
interface Serial2/1.1 point-to-point
ip address 145.1.45.5 255.255.255.0
frame-relay interface-dlci 111
Am I missing some thing here..
Thanks in advance.
prem
This archive was generated by hypermail 2.1.4 : Tue May 01 2007 - 08:28:38 ART