RE: VPN 3005 Concentrator

From: Christopher M. Heffner (cheffner@certified-labs.com)
Date: Mon Feb 05 2007 - 19:27:25 ART


Or you can just use a rj-45 couple with another short rolled cable to
get it back to be a straight thru cable.

FYI - The 3002 Hardware client is a standard rolled cable and not a
straight through cable like the VPN3K boxes.

Later.

Christopher M. Heffner, CCIE 8211, CCSI 98760
Strategic Network Solutions, Inc.
 
 
 

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Scott Morris
Sent: Sunday, February 04, 2007 2:47 PM
To: anthony.sequeira@thomson.com; bdennis@internetworkexpert.com;
security@groupstudy.com; ccielab@groupstudy.com
Subject: RE: VPN 3005 Concentrator

I suppose that would be usable... But it'd seem a whole lot easier to
have
two of the 9-pin to RJ-45 connectors with just a generic, all-purpose
patch
cable in the middle.

Call me silly. But it's easier to carry around! *shrug*

HTH,

 
Scott Morris, CCIE4 (R&S/ISP-Dial/Security/Service Provider) #4713,
JNCIE
#153, MCSE, CCDP, CCNA-WAN Switching, CCSP, Cable Communications
Specialist,
IP Telephony Support Specialist, IP Telephony Design Specialist, CISSP
CCSI #21903, JNCI-M, JNCI-J
swm@emanon.com
 
 

-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
anthony.sequeira@thomson.com
Sent: Sunday, February 04, 2007 11:13 AM
To: bdennis@internetworkexpert.com; security@groupstudy.com;
ccielab@groupstudy.com
Subject: RE: VPN 3005 Concentrator

Thanks everyone - for now I am going laptop to Concentrator.

Can you please confirm this is the correct cable.....

http://www.lindy.com/us/productfolder/03/31/31573/index.php

Thanks in advance!

________________________________

From: Brian Dennis [mailto:bdennis@internetworkexpert.com]
Sent: Saturday, February 03, 2007 2:54 PM
To: Sequeira, Anthony (NETg); security@groupstudy.com;
ccielab@groupstudy.com
Subject: Re: VPN 3005 Concentrator

Forgot to add:

What I have found is that it's easier when using an access server to
either
connect the VPN concentrator via the access server's aux port using a
straight through Ethernet cable or by using a "rolled" DB9 adapter on
the
VPN concentrator. Since the access server's octal cable is rolled,
using a
rolled DB9 adapter will make it straight through connection.

--

Brian Dennis, CCIE4 #2210 (R&S/ISP-Dial/Security/SP) bdennis@internetworkexpert.com

Internetwork Expert, Inc. http://www.InternetworkExpert.com Toll Free: 877-224-8987 Direct: 775-745-6404 (Outside the US and Canada)

On 2/3/07 11:45 AM, "Brian Dennis" <bdennis@internetworkexpert.com> wrote:

Use a straight through cable as opposed to a rolled cable.

http://www.cisco.com/univercd/cc/td/doc/product/vpn/vpn3000/3_5/getting/ gs2inst.htm#1050260

--

Brian Dennis, CCIE4 #2210 (R&S/ISP-Dial/Security/SP) bdennis@internetworkexpert.com

Internetwork Expert, Inc. http://www.InternetworkExpert.com Toll Free: 877-224-8987 Direct: 775-745-6404 (Outside the US and Canada)



This archive was generated by hypermail 2.1.4 : Thu Mar 01 2007 - 07:38:46 ART