From: Kamal N Malhotra (kmalhotr@cisco.com)
Date: Sat Feb 03 2007 - 18:01:32 ART
Hi Zahid,
No. You need not have security plus on both for failover to work. Whoever
says that you need it, is wrong. In order to have failover work, you need
security plus on atleast one box, the other might have "failover only"
license. But if you want Active/Active failover to work, then you need
security plus on both.
http://www.cisco.com/univercd/cc/td/doc/product/multisec/asa_sw/v_70/config/
failover.htm#wp1047269
HTH,
Thanks and warm regards,
Kamal N Malhotra
TAC Engineer - VPN
Cisco Systems Inc.
-----Original Message-----
From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of
Zahid Hassan
Sent: Saturday, February 03, 2007 2:06 PM
To: Security GroupStudy; R&S CCIE GroupStudy
Subject: ASA 5510 License Requirement for Security Lab
Dear All,
Can anyone please clarify if its really necessary
to have two ASA 5510 with Security Plus license.
Will failover configuration work if one is with
Security Plus and the other with Base license ?
Thanks in advance for any input on this.
Regards,
Zahid
CCIE #14103 (R&S/SP)
This archive was generated by hypermail 2.1.4 : Thu Mar 01 2007 - 07:38:45 ART