From: ELDHO PAUL (cciein2006@gmail.com)
Date: Mon Jul 03 2006 - 01:06:15 ART
I dont think so
For Example I can create a multilink interface and do the following
interface virtual-template 1
ppp multilink group 1
interface ser0/0
frame-relay interface-dlci <dlci number > ppp Virtual-Template1
On 7/3/06, Michael Stout <michaelgstout@hotmail.com> wrote:
>
> i think multilink ppp over frame would be very ugly.
> interface ser0/0
> interface virtual-temple 1
> interface multilink 2
>
> very nasty when contrasted against this:
>
> interface mfr 1
> ,,,
> interface ser 0/0
> encap frame MFR1
>
>
>
> ------------------------------
> From: *"ELDHO PAUL" <cciein2006@gmail.com>*
> Reply-To: *"ELDHO PAUL" <cciein2006@gmail.com>*
> To: *ccielab@groupstudy.com*
> Subject: *Multilink Frame Relay and Multilink ppp over frame Relay*
> Date: *Mon, 3 Jul 2006 09:00:50 +0530*
>
>
> Group,
>
> I'm unable to understand in which scinario to use multilink Frame relay
> config and in which scinario to use multilink ppp over frame-relay..
> Can anybody throw some lite on it.
>
> Regards,
> Eldho.
>
> _______________________________________________________________________
> Subscription information may be found at:
> http://www.groupstudy.com/list/CCIELab.html
This archive was generated by hypermail 2.1.4 : Tue Aug 01 2006 - 07:13:46 ART