Re: interfaces w/ OSPF network types

From: Chris Broadway (midatlanticnet@gmail.com)
Date: Wed Jun 14 2006 - 15:05:22 ART


If my understanding of the question is correct, I would look at the default
network type on R6 and then make sure R1, R4, and R5 are the same by using
the "ip ospf network type" (if needed that is). And yes, depending on the
default OSPF type on R6, you might need neighbor statements.

-Broadway

On 6/14/06, Mike O <mikeeo@msn.com> wrote:
>
> I have a question that I thought I would throw out.
>
> If you have a situation where some of your frame-relay interfaces are
> allowed to have the ospf network type defined and then some not. Whats the
> best way to configure that? For example say you have a hub and spoke with
> R1
> as the hub as R4,5 and 6 as the spoke. R6 cannot use "ip ospf network" but
> everyone else can. Do you just use neighbor? or better yet say you must
> use
> network type on R4.
>
> Is it always better to fall back and use the neighbor command when you
> can't
> get anything else to work? considering you are allowed to use the neighbor
> command in the given section.
>